Installation, Positioning and levelling, Electrical connection – Hotpoint Ariston CE6IFA.F X F-HA S User Manual

Page 24: Nl2 l1 l3 p

Advertising
background image

24

GB

! Before operating your new appliance please read
this instruction booklet carefully. It contains important
information concerning the safe installation and
operation of the appliance.

! Please keep these operating instructions for future
reference. Make sure that the instructions are kept with
the appliance if it is sold, given away or moved.

! The appliance must be installed by a qualified
professional in accordance with the instructions
provided.

! Any necessary adjustment or maintenance must be
performed after the cooker has been disconnected
from the electricity supply.

Positioning and levelling

! It is possible to install the appliance alongside
cupboards whose height does not exceed that of the
hob surface.

! Make sure that the wall in contact with the back of
the appliance is made from a non-flammable, heat-
resistant material (T 90°C).

To install the appliance correctly:
• Place it in the kitchen, the dining room or the bed-sit

(not in the bathroom).

• If the top of the
hob is higher than
the cupboards, the
appliance must be
installed at least 600 mm
away from them.
• If the cooker is
installed underneath a
wall cabinet, there must
be a minimum distance
of 420 mm between this

cabinet and the top of the hob.

This distance should be increased to 700 mm if the wall

cabinets are flammable (see fi gure).

• Do not position blinds behind the cooker or less than

200 mm away from its sides.

• Any hoods must be installed according to the

instructions listed in the relevant operating manual.

Levelling

If it is necessary to level the
appliance, screw the adjustable
feet into the places provided on
each corner of the base of the
cooker (see fi gure).

The legs* fit into the slots on the
underside of the base of the
cooker.

Electrical connection

Fitting the power supply cable
To open the terminal board:
• Insert a screwdriver into the side tabs of the terminal

board cover.

• Pull the cover to
open it.

To install the cable,

follow the instructions below:
• Loosen the cable clamp screw and the wire contact

screws.

! The jumpers are pre-set at the Factory for 230 V
single-phase connection (see fi gure).

N

L

230V ~

H05RR-F 3x4 CEI-UNEL 35363

1

3

2

4

5

H05VV-F 3x4 CEI-UNEL 35746

• To carry out the electrical connections as shown in

the figures, use the two jumpers inside the box (see
fi gure

- labelled “P”).

N

L2

L1

L3

P

Installation

HOOD

420

Min.

min.

650

mm. with hood

min.

700

mm. without hood

mm.

600

Min.

mm.

420

Min.

mm.

Advertising