Hotpoint Ariston CE6IFA.F X F-HA S User Manual

Page 25

Advertising
background image

GB

25

N

L2 L1

400V 2N~

H05RR-F 4x4 CEI-UNEL 35363

H05VV-F 4x4 CEI-UNEL 35746

1

3

2

4

5

N

L3

L1

L2

400V 3N~

H05RR-F 5x2.5 CEI-UNEL 35363

H05VV-F 5x2.5 CEI-UNEL 35746

1

3

2

4

5

• Secure the power supply cable by fastening the

cable clamp screw then put the cover back on.

Connecting the supply cable to the electricity mains
The appliance must be directly connected to the mains
using an omnipolar switch with a minimum contact
opening of 3 mm installed between the appliance and
the mains. The switch must be suitable for the charge
indicated and must comply with current electrical
regulations (the earthing wire must not be interrupted
by the switch). The supply cable must be positioned
so that it does not come into contact with temperatures
higher than 50°C at any point.

Before connecting the appliance to the power supply,
make sure that:
• The appliance is earthed and the plug is compliant with

the law.

• The socket can withstand the maximum power of the

appliance, which is indicated by the data plate.

• The voltage is in the range between the values

indicated on the data plate.

• Do not use extension cords or multiple sockets.

! Once the appliance has been installed, the power
supply cable and the electrical socket must be easily
accessible.

! The cable must not be bent or compressed.

! The cable must be checked regularly and replaced
by authorised technicians only.

! The manufacturer declines any liability should
these safety measures not be observed.

TABLE OF CHARACTERISTICS
Oven dimensions
(HxWxD)

32x43.5x40 cm

Volume

57 l

Useful
measurements
relating to the
oven
compartment

width 42 cm
depth 44 cm

height 8.5 cm

Voltage and
frequency

see data plate

ENERGY LABEL

Directive 2002/40/EC on the label
of electric ovens. Standard EN
50304

Declared energy consumption for
Forced convection Class – heating

mode: Gratin

EC Directives: 2006/95/EC dated
12/12/06(Low Voltage) and
subsequent amendments -

2004/108/EC dated 15/12/04
(Electromagnetic Compatibility)
and subsequent amendments -

90/396/EEC dated 29/06/90 (Gas)
and subsequent amendments -
93/68/EEC dated 22/07/93 and

subsequent amendments -
2002/96/EC.
1275/2008 (Stand-by/Off mode)

Data plate, is located inside the flap or, after the oven
compartment has been opened, on the left-hand wall
inside the oven.