Pump maintenance and repair - section e – Gorman-Rupp Pumps UNIT 608 1347755 thru 1395613 User Manual
Page 21
UNIT SERIES
OM−01228
MAINTENANCE & REPAIR
PAGE E − 1
PUMP MAINTENANCE AND REPAIR - SECTION E
MAINTENANCE AND REPAIR OF THE WEARING PARTS OF THE PUMP WILL MAINTAIN PEAK
OPERATING PERFORMANCE.
LIFT
(FT./M)
EDUCTOR CAPACITY
(GPM/LPH)
VACUUM
(IN. OF HG./BAR)
5
1,5
10
3,0
15
4,6
20
6,1
3.25
738
2.70
613
1.84
418
0.60
137
15
1,03
16
1,10
16
1,10
18
1,24
/
/
/
/
/
/
/
/
/
/
/
/
BACKFLUSH = 7.5 GPM (28,4 LPM) @25 PSI (1,7 BAR).
TRANSFER FLOW = 81 GPM (307 LPM) THROUGH PUMP WITH 1−1/2 INCH HOSE.
STANDARD PERFORMANCE FOR UNIT 608 tankleenor
r
Based on 70_ F (21_ C) clear water at sea level
with minimum suction lift. Since pump installations
are seldom identical, your performance may be dif-
ference due to such factors as viscosity, specific
gravity, elevation, temperature, and impeller trim.
If your pump serial number is followed by an N",
your pump is NOT a standard production model.
Contact the Gorman-Rupp Company to verify per-
formance or part numbers.