Gorman-Rupp Pumps UNIT 608 1347755 thru 1395613 User Manual

Page 35

Advertising
background image

OM−01228

UNIT SERIES

MAINTENANCE & REPAIR

PAGE E − 15

INTERMEDIATE

IMPELLER
SHAFT

IMPELLER

SPRING

RETAINER

DRIVE BAND

BELLOWS

STATIONARY
SEAT

ROTATING
ELEMENT

STATIONARY
ELEMENT

IMPELLER
SHIMS

SPRING
RETAINER

Figure 7. 25271−821 Seal Assembly

This seal is not designed for operation at
temperatures above 160

_F (71_C). Do not

use at higher operating temperatures.

Position the intermediate bracket (6) on a flat sur-
face with the impeller side facing up. Subassemble
the stationary element and seat, and use even
pressure to press this subassembly into the inter-
mediate bracket until squarely seated in the inter-
mediate bore.

Carefully slide the assembled intermediate and
stationary seal components over the motor shaft
and secure the intermediate to the motor with the
hardware (12 and 13).

Subassemble the rotating element into the retainer
and bellows. Lubricate the I.D. of the bellows with

water, and slide this subassembly onto the shaft
until the polished faces contact. Install the seal
spring and spring retainer.

Impeller Installation

(Figure 2)

Inspect the impeller and replace it if cracked or
badly worn.

For maximum pump efficiency, the impeller should
be centered within the vane plate scroll.

To verify the impeller positioning, measure the
vane plate and impeller as shown in Figure 8. Use
these measurements to calculate the required im-
peller location (dimension E). Add or remove im-
peller adjusting shims (14) until dimension E is ob-
tained.

Advertising