Gorman-Rupp Pumps UNIT 608 1347755 thru 1395613 User Manual

Page 9

Advertising
background image

OM−01228

UNIT SERIES

PAGE B − 2

INSTALLATION

Gorman-Rupp distributor or the factory to deter-
mine the repair or updating policy. Do not put the
pump into service until appropriate action has
been taken.

UNIT INSTALLATION

Lifting

This unit is mounted on a two-wheel moveable
base. It weighs approximately 260 pounds (118 ki-
lograms) including suction and discharge hoses
and the standpipe. If it is necessary to lift the unit,
use lifting equipment with a capacity of 5 times the
weight of the unit to ensure safe lifting.

Use lifting and moving equipment in

good repair and with adequate capacity
to prevent injuries to personnel or dam-
age to equipment.

Mounting

Locate the pump in an accessible place as close as
practical to the liquid being pumped. Level mount-
ing is essential for proper operation.

The pump may have to be supported or shimmed
to provide for level operation or to eliminate vibra-
tion.

Specifications

See Table 1 for typical pump specifications.

Table 1. Pump Specifications

Pump
Model

Voltage

Phase

Horse-

power

Motor

RPM

Cycle

Suction

Coupler

Discharge

Coupler

02D3

115/230

1

1

3450

60 Hz

1−1/2"

1−1/2"

See Table 1 for typical pump specifications.

Table 2. Unit Specifications

Power
Cable

Reel

Assembly

Suction

Hose

Ground

Wire

Standpipe Length

(Min) − (Max)

50 Ft.

(15,2 M.)

1−1/2" x 15 Ft.

38,1 MM x 4,6 M

10 Ft.

(3,1 M.)

42 Ft.

(12,8 M.)

Discharge

Hose

1−1/2" x 15 Ft.

38,1 MM x 4,6 M

7.25 Ft. − 12 Ft.

2,2 M − 3,7 M

Positioning Unit and Setup

Figure 2 shows a typical installation of the tank-
leenor

t system.

Advertising