ULTRA V SERIES

OM-06014

OPERATION

PAGE C - 2

If rotation is incorrect on a three‐phase motor, have
a qualified electrician interchange any two of the
three phase wires to change direction. If rotation is
incorrect on a single‐phase motor, consult the liter­
ature supplied with the motor for specific instruc­
tions.

OPERATION

Lines With a Bypass

If a Gorman‐Rupp Automatic Air Release Valve has
been installed, the valve will automatically open to
allow the pump to prime, and automatically close
after priming is complete (see INSTALLATION for
Air Release Valve operation).

If the bypass line is open, air from the suction line
will be discharged through the bypass line back to
the wet well during the priming cycle. Liquid will
then continue to circulate through the bypass line
while the pump is in operation.

Lines Without a Bypass

Open all valves in the discharge line and start the
power source. Priming is indicated by a positive
reading on the discharge pressure gauge or by a
quieter operation. The pump may not prime imme­
diately because the suction line must first fill with
liquid. If the pump fails to prime within five minutes,
stop it and check the suction line for leaks.

After the pump has been primed, partially close the
discharge line throttling valve in order to fill the line
slowly and guard against excessive shock pres­
sure which could damage pipe ends, gaskets,
sprinkler heads, and any other fixtures connected
to the line. When the discharge line is completely
filled, adjust the throttling valve to the required flow
rate.

Do not operate the pump against a
closed discharge throttling valve for
long periods of time. If operated against
a closed discharge throttling valve,

pump components will deteriorate, and
the liquid could come to a boil, build
pressure, and cause the pump casing to
rupture or explode.

Leakage

No leakage should be visible at pump mating sur­
faces, or at pump connections or fittings. Keep all
line connections and fittings tight to maintain maxi­
mum pump efficiency.

Liquid Temperature And Overheating

The maximum liquid temperature for this pump is
160

_F (71_C). Do not apply it at a higher operating

temperature.

Overheating can occur if operated with the valves
in the suction or discharge lines closed. Operating
against closed valves could bring the liquid to a
boil, build pressure, and cause the pump to rup­
ture or explode. If overheating occurs, stop the
pump and allow it to cool before servicing it. Refill

the pump casing

with cool liquid.

Allow an over‐heated pump to com­
pletely cool before servicing

.

Do not re­

move plates, covers, gauges, or fittings
from an over‐heated pump. Liquid with­
in the pump can reach boiling tempera­
tures, and vapor pressure within the
pump can cause parts being disen­
gaged to be ejected with great force. Af­
ter the pump completely cools, drain
the liquid from the pump by removing
the casing drain plug. Use caution when
removing the plug to prevent injury to
personnel from hot liquid.

As a safeguard against rupture or explosion due to
heat, this pump is equipped with a pressure relief
valve which will open if vapor pressure within the
pump casing reaches a critical point. If overheating
does occur, stop the pump immediately and allow
it to cool before servicing it. Approach any over­