Gorman-Rupp Pumps VS6A60-B 1321070 thru 1352520 User Manual

Page 41

Advertising
background image

OM-06014

ULTRA V SERIES

MAINTENANCE & REPAIR

PAGE E - 17

Lubricate the external stationary seat O‐ring with
light oil. Slide the seal assembly onto the shaft until
the external stationary seat O‐ring engages the
bore in the seal plate.

Clean and inspect the impeller as described in Im­
peller Installation and Adjustment
. Install the full
set of impeller shims (2) provided with the seal, and
screw the impeller onto the shaft until it is seated
against the seal (see Figure 9).

O‐RING ENGAGED

WITH SEAL PLATE

BORE

SHEAR RING

(UNSHEARED)

Figure 9. Seal Partially Installed

Continue to screw the impeller onto the shaft. This
will press the stationary seat into the seal plate
bore.

NOTE

A firm resistance will be felt as the impeller presses
the stationary seat into the seal plate bore.

STATIONARY SEAT

FULLY SEATED IN

SEAL PLATE BORE

SHEAR RING

(SHEARED)

Figure 10. Seal Fully Installed

As the stationary seat becomes fully seated, the
seal spring compresses, and the shaft sleeve will
break the nylon shear ring. This allows the sleeve
to slide down the shaft until seated against the
shaft shoulder. Continue to screw the impeller onto
the shaft until the impeller, shims, and sleeve are
fully seated against the shaft shoulder (see Figure
10).

Measure the impeller‐to‐seal plate clearance, and
remove impeller adjusting shims to obtain the
proper clearance as described in Impeller Instal­
lation and Adjustment
.

If necessary to reuse an old seal in an emer­
gency, carefully separate the rotating and station­
ary seal faces from the bellows retainer and sta­
tionary seat.

A new seal assembly should be installed
any time the old seal is removed from the
pump. Wear patterns on the finished faces
cannot be realigned during reassembly.
Reusing an old seal could result in prema­
ture failure.

Handle the seal parts with extreme care to prevent
damage. Be careful not to contaminate precision
finished faces; even fingerprints on the faces can
shorten seal life. If necessary, clean the faces with a
non‐oil based solvent and a clean, lint‐free tissue.
Wipe lightly in a concentric pattern to avoid
scratching the faces.

Carefully wash all metallic parts in fresh cleaning
solvent and allow to dry thoroughly.

Do not attempt to separate the rotating
portion of the seal from the shaft sleeve
when reusing an old seal. The rubber bel­
lows will adhere to the sleeve during use,
and attempting to separate them could
damage the bellows.

Inspect the seal components for wear, scoring,
grooves, and other damage that might cause leak­
age. Inspect the integral shaft sleeve for nicks or

Advertising