Pump maintenance and repair - section e – Gorman-Rupp Pumps 06C1-GA 1005575 and up User Manual
Page 20
0 SERIES
OM−01247
MAINTENANCE & REPAIR
PAGE E − 1
PUMP MAINTENANCE AND REPAIR - SECTION E
MAINTENANCE AND REPAIR OF THE WEARING PARTS OF THE PUMP WILL MAINTAIN PEAK
OPERATING PERFORMANCE.
STANDARD PERFORMANCE FOR PUMP MODELS 06C1−GA AND 06C3−GA
Based on 70_ F (21_ C) clear water (corrected to
0.8 specific gravity) at sea level with minimum suc-
tion lift. Since pump installations are seldom identi-
cal, your performance may be different due to such
factors as viscosity, specific gravity, elevation, tem-
perature, and impeller trim.
If your pump serial number is followed by an N",
your pump is NOT a standard production model.
Contact the Gorman-Rupp Company to verify part
numbers.
Pump speed and operating condition
points must be within the continuous per-
formance range shown on the curve.