SUPER T SERIES

OM-05604

PAGE A - 2

SAFETY

Do not operate the pump against a
closed discharge valve for long periods
of time. If operated against a closed dis­
charge valve, pump components will
deteriorate, and the liquid could come
to a boil, build pressure, and cause the
pump casing to rupture or explode.

Do not attempt to disengage any part of
an overheated pump unit. Vapor pres­
sure within the pump casing can eject
these parts with great force when they
are disengaged. Allow the pump to
completely cool before servicing it.

Overheated pumps can cause severe
burns and injury. If overheating of the
pump occurs:

1. Stop the pump immediately.
2. Allow the pump to completely cool.
3. Refer to instructions in this manual

before restarting the pump.

Use lifting and moving equipment in
good repair and with adequate capacity
to prevent injuries to personnel or dam­
age to equipment. Suction and dis­
charge hoses and piping must be re­
moved from the pump before lifting.

Pumps and related equipment must be in­
stalled and operated according to all na­
tional, local and industry standards.