Gorman-Rupp Pumps PA4A60C-B-E30 575/3 1482736 and up User Manual

Page 47

Advertising
background image

PA SERIES

OM−06440

MAINTENANCE & REPAIR

PAGE E − 20

clean as required before proceeding with seal
installation.

Lubricate the external stationary seat O-ring with
light oil. Slide the seal assembly onto the shaft until
the external stationary seat O-ring engages the
bore in the seal plate.

Clean and inspect the impeller as described in Im-
peller Installation and Adjustment. Install half of
the set of impeller shims (2) provided with the seal,
and screw the impeller onto the shaft until it is
seated against the seal (see Figure 10).

O-RING ENGAGED

WITH SEAL PLATE

BORE

SHEAR RING

(UNSHEARED)

Figure 10. Seal Partially Installed

Continue to screw the impeller onto the shaft. This
will press the stationary seat into the seal plate
bore.

NOTE

A firm resistance will be felt as the impeller presses
the stationary seat into the seal plate bore.

As the stationary seat becomes fully seated, the
seal spring compresses, and the shaft sleeve will
break the nylon shear ring. This allows the sleeve
to slide down the shaft until seated against the
shaft shoulder. Continue to screw the impeller onto
the shaft until the impeller, shims, and sleeve are
fully seated against the shaft shoulder (see Figure
11).

STATIONARY SEAT

FULLY SEATED IN

SEAL PLATE BORE

SHEAR RING

(SHEARED)

Figure 11. Seal Fully Installed

Measure the impeller-to-seal plate clearance, and
add or remove impeller adjusting shims to obtain
the proper clearance as described in Impeller In-
stallation and Adjustment.

If necessary to reuse an old seal in an emer-
gency, carefully separate the rotating and station-
ary seal faces from the bellows retainer and sta-
tionary seat.

A new seal assembly should be installed
any time the old seal is removed from the
pump. Wear patterns on the finished faces
cannot be realigned during reassembly.
Reusing an old seal could result in prema-
ture failure.

Handle the seal parts with extreme care to prevent
damage. Be careful not to contaminate precision
finished faces; even fingerprints on the faces can
shorten seal life. If necessary, clean the faces with a
non-oil based solvent and a clean, lint-free tissue.
Wipe lightly in a concentric pattern to avoid
scratching the faces.

Carefully wash all metallic parts in fresh cleaning
solvent and allow to dry thoroughly.

Do not attempt to separate the rotating
portion of the seal from the shaft sleeve

Advertising