Gorman-Rupp Pumps PA4A60C-B-E30 575/3 1482736 and up User Manual

Page 50

Advertising
background image

OM−06440

PA SERIES

MAINTENANCE & REPAIR

PAGE E − 23

LUBRICATION

(Figure 4)

Seal Assembly

Before starting the pump, remove the vented plug
(10) and fill the seal cavity with approximately 5
quarts (4,7 liters) of SAE No. 30 non-detergent oil
or to the center of the sight gauge (13). Clean and
reinstall the vented plug. Maintain the oil level at the
middle of the sight gauge.

Bearings

(Figure 4)

The bearing housing was fully lubricated when
shipped from the factory. Check the oil level regu-
larly through the sight gauge (13A)

and maintain it

at the midpoint of the gauge. When lubrication is
required, remove the air vent (12) and add SAE No.
30 non-detergent oil through the opening. When
lubricating a dry (overhauled) intermediate, fill the
bearing cavity with approximately 28 ounces (0,8
liter). Clean and reinstall the air vent. Do not over-

lubricate. Over-lubrication can cause the bearings
to over-heat, resulting in premature bearing failure.

NOTE

The white reflector in the sight gauge must be posi-
tioned horizontally to provide proper drainage.

Under normal conditions, drain the bearing hous-
ing once each year and refill with clean oil. Change
the oil more frequently if the pump is operated con-
tinuously or installed in an environment with rapid
temperature change.

Monitor the condition of the bearing lubri-
cant regularly for evidence of rust or mois-
ture condensation. This is especially im-
portant in areas where variable hot and
cold temperatures are common.

For cold weather operation, consult the factory or a
lubricant supplier for the recommended grade of
oil.