OM−06488

SE SERIES

PAGE B − 7

INSTALLATION

pump must be approved by the Gor-
man-Rupp Company for the application.

Motor Cable Grounding Test

Do not connect the pump control cable
incoming voltage before verifying the
pump ground; otherwise, personnel will
be exposed to serious injury or death.

Liquid Level Devices

The pump is not furnished with a means to auto-

matically regulate liquid level. It may be controlled

to perform filling and dewatering by using the float

switch and liquid level control offered as options

(see Figure B−5).

Overheating will occur if the liquid level falls
below the level required to cool the pump
motor (see LIQUID LEVEL in Operation,
Section C).

PUMP

CONTROL BOX

LIQUID LEVEL

RANGE

ON (FILLING)

TO LEVEL CONTROL CIRCUIT

IN MAIN CONTROL BOX

OFF

DEWATERING

PUMP

CONTROL BOX

TO LEVEL CONTROL CIRCUIT

IN MAIN CONTROL BOX

LIQUID LEVEL

RANGE

OFF

DEWATERING

ON (FILLING)

Figure B−5. Typical Float Switch Installation