Gorman-Rupp Pumps SE1 1/2A3 115V 1P 1483930 and up User Manual
Page 14
OM−06488
SE SERIES
PAGE B − 7
INSTALLATION
pump must be approved by the Gor-
man-Rupp Company for the application.
Motor Cable Grounding Test
Do not connect the pump control cable
incoming voltage before verifying the
pump ground; otherwise, personnel will
be exposed to serious injury or death.
Liquid Level Devices
The pump is not furnished with a means to auto-
matically regulate liquid level. It may be controlled
to perform filling and dewatering by using the float
switch and liquid level control offered as options
(see Figure B−5).
Overheating will occur if the liquid level falls
below the level required to cool the pump
motor (see LIQUID LEVEL in Operation,
Section C).
PUMP
CONTROL BOX
LIQUID LEVEL
RANGE
ON (FILLING)
TO LEVEL CONTROL CIRCUIT
IN MAIN CONTROL BOX
OFF
DEWATERING
PUMP
CONTROL BOX
TO LEVEL CONTROL CIRCUIT
IN MAIN CONTROL BOX
LIQUID LEVEL
RANGE
OFF
DEWATERING
ON (FILLING)
Figure B−5. Typical Float Switch Installation