Liberty Pumps ProVore 380 User Manual

Page 7

Advertising
background image

©Copyright 2013 Liberty Pumps Inc. All rights reserved 7

QuickTree

®

settings for ProVore

®

Systems:

When servicing the QuickTree

®

place the switch cord into the trough or channel then slip the stainless steel rod through the clamp and

tighten the screw with a Philips screw driver do not over tighten. Flats have been formed on the rod to designate float positioning the

screw should be tightened onto the flat. The tether length is the amount of cord between the clamp and float.

ROD

POSITION Alarm Float Control Float

1

3.5"

2

3

3.0"

4

P380 & P680

TETHER LENGTH

(SWITCH TO CLAMP)

Float positions 1, 2, 3 and 4

are identified by a “flat”

stamped into the stainless

steel rod. 1 is highest, 4 is

lowest.

Control and alarm floats have different tether

lengths. See above chart for proper tether length

and correct rod position.