Elmo Rietschle C-VLR 1000 User Manual

Page 13

Advertising
background image

13

www.gd-elmorietschle.com © Gardner Denver Schopfheim GmbH, Gardner Denver Deutschland GmbH

|

Bauj./Nr. 09

S1 3,00 / 3,60

kW

Typ VTR 100 (01)

150 mbar (abs.)

2849751

100 / 120 m³/h

EN 60034

1410 / 1700 min

-1

1027610116

3~

Mot.

Set up and operation

6

1

7

8

9

10

3

4

5

2

4.1.1 Data plate

Fig. 3 Data plate (example)

1

Type/ Size (mechanical version)

2

Year of construction

3 Motor

design

4 Serial

number

5 Item

no.

6

Final pressure (abs.)

7

Pumping capacity 50 Hz / 60 Hz

8 Speed

50

Hz / 60

Hz

9

Motor output 50 Hz / 60 Hz

10 Operating

mode

4.2

Description

The C-VLR 1000 model has a connection fl ange on the inlet side and an exhaust silencer on the pressure
side (Fig. 2/B

1

). The air sucked in is cleaned by a micro-fi lter (Fig. 2/S).

The ZEPHYR VLR 1000 is a double shaft rotary piston vacuum pump in which the claws roll off against each
other contact free and dry. The counter-rotating claw rotors are synchronised by a gear pair in the gearbox.
The synchronous gearbox gear wheels and the bearings are lubricated with oil. These components are in
a gearbox that also contains the oil supply. Oil conveying devices always ensure that the bearings and the
gear wheels are suffi ciently supplied with oil at all permissible speeds.
The gearbox and the compression chamber are separated from each other by special seals. The gearbox
is sealed from the outside with shaft seals and O rings, the compressor chamber with piston rings.The
VLR 1000 is enclosed in an insulating hood. In order to dissipate compression heat, the cooling air is sucked
through between the machine and the hood using a drum fan that sucks in the fresh cooling air (Fig. 2/E)
and discharges the heated air out of the cooling air outlet (Fig. 2/F).
The VLR 1000 is driven by standard fl anged three-phase motors via a coupling.
A vacuum relief valve is incorporated into the machine.

4.3

Areas of application

This contact free running claw vacuum pump, the C-VLR 1000, can be operated constantly at any pressure
between atmospheric and an inlet pressure of 200 mbars (abs.).

The pumping capacity with unrestricted suction is 950 m

3

/h at 50 Hz. Data sheet D 880/80 shows the de-

pendency of the pumping capacity on the intake pressure.

If the unit is switched on more frequently (at regu-
lar intervals of about 10 times an hour) or at higher
ambient temperatures and intake temperatures, the
excess temperature limit of the motor winding and
the bearings may be exceeded.Please contact the
manufacturer should the unit be used under such
conditions.

If it is installed in the open air the unit must be pro-
tected from environmental infl uences, (e.g. by a pro-
tective roof).

Advertising