Malfunctions: Causes and elimination

Fault

Cause

Troubleshooting

Important

Machine is switched
off by the motor pro-
tection switch

Mains voltage/ Frequency
does not correspond with the
motor data

Check by qualifi ed electrician

Section 5.5

Connection to motor terminal
board is not correct

Motor protection switch is not
set correctly

Motor protection switch is
triggered too quickly

Use a motor protection switch
with an overload-dependent
delayed switch off that takes
into consideration the short
term excess current at start
up (version with short circuit
and overload trigger as per
VDE 0660 Part 2 orIEC 947-4)

Pumping capacity is
insuffi cient

The mesh fi lter is dirty

Clean or replace the fi lter

Section
7.2.2Section
7.4

The suction pipe is too long or
too narrow

Check the hose or the pipe

Section 5.3

Machine or system leaking

Check the pipework and
screw connections for leaks
and to ensure that they are
fi rmly seated.

Section 7.2

Final pressure (max.
vacuum) is not
reached

Machine or system leaking

Check the pipework and
screw connections for leaks
and to ensure that they are
fi rmly seated.

Section 7.2

Machine gets too hot

Ambient or intake temperature
is too high

Ensure it is being used prop-
erly

Section 2.3

Cooling air supply is ob-
structed

Check environmental condi-
tions

Section 5.1

Clean ventilation slots

Section 7.2

The machine makes
an abnormal noise

Deposits on the rotary piston

Clean the working space and
the rotary piston

Elmo Rietschle
Service

Please contact Elmo Rietschle Service for other malfunctions or those that cannot be eliminated.

8

Malfunctions: Causes and elimination

Advertising