7.2.1 Changing the oil

Fig. 4 Changing the oil

H

Oil fi lling point

I

Oil sight glass

K

Oil discharge point

M

Oil recommendation plate

S Mesh

fi lter

NOTICE

Always change the oil when the machine is at
operating temperature and in an atmospherically
ventilated area.
If it is not completely emptied the amount that can
be refi lled is reduced.

The waste oil must be disposed of in compliance with
the local environmental protection regulations.
If you are going to use another oil type, empty the
oil removing device housing and oil cooler com-
pletely.

The oil level in the sight glasses (Fig. 4/I) must be
checked every month.
The machine must be switched off and vented to at-
mospheric pressure to top up the oil.With clean op-
erations the oil must be changed after every 8,000
operating hours..
The oil viscosity must comply with ISO VG 150 as
per DIN 51519.
Designation as per DIN 51502: CLP HC 150.
GEAR-LUBE 150 or equivalent oils by other manu-
facturers (also see oil recommendation plate (Fig. 4/
M)).