Elmo Rietschle C-DLR 60/100/120/150/250/300/400/500 User Manual

Page 21

Advertising
background image

21

www.gd-elmorietschle.com © Gardner Denver Schopfheim GmbH, Gardner Denver Deutschland GmbH

|

Maintenance and repair

7

Maintenance and repair

DANGER

Danger of death from touching live parts.
Before maintenance work disconnect the machine
by pressing the main switch or unplugging it and
ensure that it cannot be turned on again.

WARNING

Hot surfaces
During maintenance work there is the danger of
getting burnt on hot components (Fig. 2/Q... 4/Q)
of the machine.
Wait for the machine to cool down.

7.1 Ensuring

operational

safety

Regular maintenance work must be carried out in order to ensure operational safety.

Maintenance intervals also depend on the operational demands on the machine.

With any work observe the safety instructions described in Section 2.8 “Safety notes for installation, com-
missioning and maintenance”.

The whole unit should always be kept in a clean condition.

7.2 Maintenance

work

Interval

Maintenance to be carried out

Section

monthly

Check the pipes and screws for leaks and to ensure they are
seated properly and if necessary seal again or tighten up.

monthly

Check the terminal box and cable inlet holes for leaks and if
necessary re-seal.

monthly

Clean the safety valve and ventilation slots on the machine
and the motor cooling ribs.

10.000 h

Replace the safety valve

monthly

Check the oil level

7.2.1

5.000 h

Changing the oil

5.000 h

C-DLR 400 / 500: Lubricate the bearing on the side facing

away from the motor

monthly/ every 6 months

C-DLR 60, 100 / 120 (09): Clean or replace fi lter cartridge

7.2.2

depending on how dirty the
discharged medium is

C-DLR 100 - 500: Clean the micro fi lter

at least once a year

C-DLR 100 / 120/ 150:

Check for coupling wear

7.2.3

Advertising