Elmo Rietschle C-DLR 60/100/120/150/250/300/400/500 User Manual

Page 29

Advertising
background image

29

www.gd-elmorietschle.com © Gardner Denver Schopfheim GmbH, Gardner Denver Deutschland GmbH

|

Malfunctions: Causes and elimination

Fault

Cause

Troubleshooting

Important

Final pressure (max.
excess pressure) has
not been reached

Machine or system leaking

Check the pipework and
screw connections for leaks
and to ensure that they are
fi rmly seated.

Section 7.2

Driving power selection too
low

Use next largest motor output

Data sheet D
361

Machine gets too hot

Ambient or intake temperature
is too high

Ensure it is being used prop-
erly

Section 2.3

Cooling air supply is ob-
structed

Check environmental condi-
tions

Section 5.1

Clean ventilation slots

Section 7.2

The safety valve is dirty so
that the permissible pressure
is exceeded.

Clean or replace the safety
valve

Section 7.2
Section 7.4

The machine makes
a abnormal noise

Deposits on the rotary piston

Clean the working space and
the rotary piston

Elmo Rietschle
Service

The safety valve is vibrating

Replace the valve

Section 7.4

Please contact Elmo Rietschle Service for other malfunctions or those that cannot be eliminated.

Advertising