Elmo Rietschle V-VTE 3/6/8/10 User Manual

Page 19

Advertising
background image

19

www.gd-elmorietschle.com © Gardner Denver Schopfheim GmbH, Gardner Denver Deutschland GmbH

|

Maintenance and repair

7

Maintenance and repair

DANGER

Danger of death from touching live parts.
Before maintenance work disconnect the machine
by pressing the main switch or unplugging it and
ensure that it cannot be turned on again.

WARNING

Hot surfaces
During maintenance work there is the danger of
getting burnt on hot components (Fig. 1/Q).
Wait for the machine to cool down.

7.1 Ensuring

operational

safety

Regular maintenance work must be carried out in order to ensure operational safety.

Maintenance intervals also depend on the operational demands on the machine.

With any work observe the safety instructions described in Section 2.8 “Safety notes for installation, com-
missioning and maintenance”.

The whole unit should always be kept in a clean condition.

7.2 Maintenance

work

Interval

Maintenance to be carried out

Section

monthly

Check the pipes and screws for leaks and to ensure they are
seated properly and if necessary seal again or tighten up.

monthly

Check the terminal box and cable inlet holes for leaks and if
necessary re-seal.

monthly

Clean the ventilation slots on the machine and the motor
cooling ribs.

The machine‘s bearings are permanently lubricated and do
not require re-lubricating.

monthly / yearly

Clean or replace fi lter cartridges

7.2.1

4,000 h - 1,000 h

Check blades

Replace blades

7.2.2

Advertising