7.2.1 Air fi ltering

Fig. 3 Air fi ltering and changing blades

O

1

Direction of rotation

X Minimum

height

Y

Slanting side of the blade

Z

Drilled holes in the housing

b Housing

cover

c Rotor

d Housing

e Blade

f Filter

cartridge

g

Filter room

m

Gasket

n

Gasket

s

Screws

NOTICE

Insuffi cient maintenance on the air fi lter
The power of the machine lessens and damage may
occur to the machine.

The fi lter cartridge (Fig. 3/f) air must be cleaned by
blowing from the inside to the outside once a month
or more often depending on the level of contamina-
tion, or if necessary replaced.
In spite of cleaning the filters their separation effi-
ciency will continue to deteriorate.
Therefore the fi lters should be replaced every year
(or under extreme condition more often).
Changing fi lters:
Screw off housing cover (b).
Remove fi lter cartridge (Fig.

3/f

) with gaskets (Fig. 3/

m, 3/n) from fi lter room (Fig.

3/g

). Clean or replace

fi lter cartridge and check gaskets.
Reassemble in reverse order.

Pay

attention:

a) Don’t interchange gaskets (Fig. 3/m, 3/n)

b) Ensure that the surfaces of housing (Fig. 3/d)

and rotor (Fig. 3/c) are clean

c) Tighten the screws (Fig. 3/s) to 5,5 + 0,5 Nm