Elmo Rietschle V-VC 400/500/700/900/1100/1300 User Manual

Page 25

Advertising
background image

25

www.gd-elmorietschle.com © Gardner Denver Schopfheim GmbH, Gardner Denver Deutschland GmbH

|

Maintenance and repair

L

Y

W

T

WARNING

Heavily contaminated air oil removing devices lead
to increased pump temperatures and in extreme
cases may cause the lubricating oil to ignite spon-
taneously.

The oil separator elements may be contaminated
with particles of dirt when the machine has been
running for a long time (power consumption and
pump temperature increase). Replace these com-
ponents (Fig. 10/L) every 2000 operating hours or
when the fi lter resistance is 0.7 bar (see pressure
gauge (Fig. 10/Y)

➝ Accessory, check with short

term atmospheric suction) because it is not possi-
ble to clean them.
Reduce the change intervals accordingly depending
on how contaminated the discharged medium is.
Changing: Unscrew the maintenance cover (Fig. 10/
W). Replace the oil separator elements (Fig. 10/L).
Re-assemble in reverse order. Before fi tting the O
ring lightly oil the new oil remover and tighten it to
15 Nm (wrench width 19 mm or

3

/

4

”).

Fig. 10 Oil removal

L

Oil separator element

T

Oil remover housing

W Maintenance

cover

Y

Pressure gauge (accessory)

7.2.4 Oil removal

Advertising