Elmo Rietschle V-VC 400/500/700/900/1100/1300 User Manual

Page 30

Advertising
background image

30

|

www.gd-elmorietschle.com © Gardner Denver Schopfheim GmbH, Gardner Denver Deutschland GmbH

Malfunctions: Causes and elimination

Fault

Cause

Troubleshooting

Important

The machine makes
a abnormal noise

(The blades making
a hammering noise
when starting from
cold is normal if it
disappears within
two minutes as the
operating tempera-
ture increases)

The coupling rubbers are
worn

Replace coupling rubbers

Section 7.2.1

The pump housing is worn
(chatter marks)

Repair by manufacturer or
authorised workshop

Elmo Rietschle
Service

The vacuum adjustment valve
(if available) is vibrating

Replace the valve

Section 7.4

Blades are damaged

Repair by manufacturer or
authorised workshop

Elmo Rietschle
Service

Vacuum pump or its oil is too
cold

Note the ambient temperature
and the intake temperature

Section 2.3

The lubricating oil is too vis-
cous

The oil viscosity must comply
with ISO VG 100 as per DIN
51519

Section 7.2.3

Water in lubricating
oil

Pump sucks in water

Install water interceptor up-
stream of the pump

The pump sucks in more wa-
ter vapour than is suitable for
its water vapour compatibility

Contact the manufacturer for
increased gas ballast

Pump only works for a short
time and therefore does not
reach its normal operating
temperature

Let the pump continue to run
with a closed suction side
after extracting the water
vapour until the water has
evaporated from the oil

Please contact Elmo Rietschle Service for other malfunctions or those that cannot be eliminated.