Installation

610.44444.40.000

14 / 36

© Gardner Denver Deutschland GmbH

Securing:

There are two options:

 Install the system without securing.
OR

 Screw the feet of the system to the surface

with suitable fasteners.

Models 2BL2 041 - 141:
Screws 4 x M10
Washers as per ISO 7093-1
Tightening torque: 10 Nm [7.38 ft lbs]

Models 2BL2 251 - 341:
Screws 4 x M12
Washers as per ISO 7093-1
Tightening torque: 20 Nm [14.81 ft lbs]

CAUTION

With the 2BL2 341 the 4 adjustment screws of
the hexagonal feet (see Fig. 1, Pg. 3) and the 3
strips of the separator must make contact over
the entire contact surface on the floor or the
raised sections.



5.2

Electrical connection (motor)

DANGER

Electrical danger!

Improper behaviour can result in severe
injuries and damage!

DANGER

Electrical danger!

The electrical connection may be carried out
by trained and authorised electricians only!

DANGER

Electrical danger!

Before beginning work on the system, the
following measures must be carried out:
 Deenergise.
 Secure against being switched on again.
 Determine

whether

deenergised.

 Ground and short-circuit.
 Cover or block off adjacent energised parts.

DANGER

Electrical danger!

Replace loose connections, singed or burned
cables immediately!

DANGER

Electrical danger!

Lay the electrical connecting cables so that
they cannot be damaged by external
influences and are free from tensile stress!

WARNING

Danger due to gauge pressure and vacuum!

Danger due to escaping fluid!

Before beginning work on the system or line:
 Interrupt supply of operating liquid.
 Vent lines (depressurise).

CAUTION

Incorrect connection of the motor can lead to
serious damage to the system!


Regulations:
The electrical connection must be carried out as
follows:

 according to the applicable national and local

laws and regulations,

 according to the applicable system-dependent

prescriptions and requirements,

 according to the applicable regulations of the

utility company.


Electrical power supply:

Observe the rating plate.
It is imperative that the operating conditions
correspond to the data given on the rating plate!

Deviations permissible without reduction in
performance:

 ±5 % voltage deviation

 ±2 % frequency deviation

Fit connecting cable:

 Use

a

flexible cable

as the electrical

connecting cable.

 Open

system:

Remove cover plate.