Servicing – Elmo Rietschle L-BL2 User Manual

Page 28

Advertising
background image

Servicing

610.44444.40.000

28 / 36

© Gardner Denver Deutschland GmbH

Contamination/Problem

Remedy

Impeller of installed unit is
jammed.

Free shaft by turning.

To do so, proceed as follows:

 Shut down system and secure against being switched on again.

 Remove cover plate (Item 064).

 Turn shaft of installed unit (Item D) by hand at fan impeller.

 If shaft cannot be freed by turning, installed unit must be decalcified.

Extremely hard water used
as operating liquid
Lime content > 15°dH).

Soften operating liquid.

OR

Decalcify installed unit.

Decalcify installed unit (Item D) at regular intervals. (Intervals are depending
on calcification.)

To do so, proceed as follows:

 Wear personal protective equipment (protective gloves and safety

goggles),

 Shut down system and secure against being switched on again.

 Drain system as described in Chapter 8.1, "Draining", Pg. 23.

 Have the cover plate (Item 064) and protective grille (Item 058) removed

from the separator.

 Models 2BL2 041 - 2BL2 141:

Disconnect pipe/hose from screw-in connecting sleeve (Item H) of
installed unit.
Models 2BL2 251 - 2BL2 341:
Disconnect pipe/hose from condensation cooler (Item 031).
To remove the pipe/hose, open the clip with special pliers or a
screwdriver.

 Use

10 % ethanoic acid

as antiliming liquid.

 WARNING: Danger from ethanoic acid! Ethanoic acid can cause heavy

acid burns! Observe applicable laws and regulations as well as accident
prevention regulations concerning hazardous substances and
manufacturer's safety data sheet!

 Fill interior of installed unit with antiliming liquid.

To do so, proceed as follows:

Pour antiliming liquid into the open screw-in connecting sleeve (Item H)
using a funnel or hose. (See Fig. 13, Pg. 24.)
Filling amount: see Chapter 3.1, "Mechanical data", Section "Filling
quantity for antiliming liquid", Pg. 8. The entire interior of the installed unit
must be filled with antiliming liquid.

CAUTION: Various system seals can be damaged by prolonged contact
to ethanoic acid. The ethanoic acid may only enter the interior of the
installed unit.