39

1. Loudspeaker
2. Tamper

contact

3. Microphone
4. Tamper

loop

5. Inputs

A-D

6. Jumper for trigger polarity
7. Telephone

connection

8. Power supply 12 V/0 V DC and output
9. Jumper for the factory settings reset

7. Connections

IMPORTANT

:

Make sure that the power supply is switched off before wiring!

7.1 General

information

Connection Description

TRIG A

When this input is triggered, the device begins transmission of

message A.

TRIG B

When this input is triggered, the device begins transmission of

message B.

TRIG C

When this input is triggered, the device begins transmission of

message C.

ABORT / D

When this input is triggered, the device begins transmission of

message D.

This input can also be used to abort dialling procedures (see

chapter 10.8 “Abort function”).

TAMP

These two connector clamps can be connected to the tamper

zone of an alarm centre. If the device housing is opened, the

sabotage loop to the centre is interrupted and a tamper alarm

is triggered.