ABUS FU8380 Secvest 2WAY Wireless Seismic Detector User Manual

Page 20

Advertising
background image

20

Jumper A



Sensitivity:

The detector can be set to high
or low sensitivity using jumper A.
The sensitivity can be fine-tuned
in the corresponding setting
range using the potentiometer
(see below).

Jumper B Multiple-vibration mode:

When the multiple-vibration mode
is activated, the vibration detector
only sends an alarm after
repeated vibrations.

Off

On

Jumper C Calibration:

Use this jumper to set the
detector to calibration mode or
normal operation.

Calibrate detector

Normal

Jumper D LED:

Use this jumper to deactivate/
activate the LED on the detector.

Off

Low
High