3 service power inserter, 0 installation, continued – Alpha Technologies UPE-M Series User Manual

Page 23

Advertising
background image

23

031-145-C0-002 Rev. B

To prevent arcing, the center conductor (stinger) of the coaxial termination must go fully inside the
seizure screw assembly. Tighten to 35 inch-pounds.

Service

Power

Inserter

3.0

Installation, continued

3.3

Service Power Inserter

Mount the SPI box(es) on the back wall of
the Power Supply compartment.

1.

Remove the two screws on the face of
the SPI and lift off the cover to gain
access to the seizure screw assembly.
Loosen the seizure screw several turns,
so the stinger will pass through the
clamp.

3,

Insert the coaxial termination into the
output port on the bottom of the SPI.
Ensure that the stinger goes through
the seizure screw assembly. Tighten
the coaxial termination.

4.

Tighten the seizure screw to 35 inch-
pounds. Replace the SPI cover and
screws. Ensure the switch on the top
or the SPI is in the ON position, the
AUX position is used only when an
alternate power source is connected to
the Jones connector on the top of the
SPI.

Seizure Screw

Assembly

Jones Connector

Fig. 3-8, Removing SPI Cover

Fig. 3-9, Connecting Coax to SPI Output Port

Seizure Screw

Assembly

Side View of SPI Case

Circuit Board

Coaxial Termination

Stinger

Enclosure

Wall

Output

Port

Stinger

Advertising