Programming & Measurement Resolution
Voltage (Front Panel)

10 mV

Current (Front Panel)

10 mA

Voltage (Remote Interface)

0.003% of Vmax

Current (Remote Interface)

0.002% of Imax

Voltage (Analog Programming Interface )

0.04% of Vmax

Current (Analog Programming Interface )

0.04% of Imax

Programming Accuracy
Voltage Programming (Front Panel and Remote Interface )

0.1% of Vmax

Voltage Programming (Analog Programming Interface )

0.2% of Vmax

Current Programming (Front Panel and Remote Interface )

0.3% of Imax

Current Programming (Analog Programming Interface )

0.3% of Imax

Programming Response Time
Rise Time : For a programmed 5% to 95% step in output voltage.(Full & No Load)

See Electrical Specification

Fall Time : For a programmed 95% to 5% step in output voltage.

(The fall time will be affected by the external loading from UUT.)
Vout setting (USB send command to DC source receiver)

10ms

Measure Volt , Current (under USB command using Fetch)

10ms

Measure Volt , Current (under USB command using Measure)

70ms

Analog Programming Interface
Voltage and Current Programming inputs

0~10Vdc or 0~5Vdc of F.S.

Voltage and Current monitor

0~10Vdc or 0~5Vdc of F.S.

Isolation : Maximum working voltage of any analog programming signal with respect to chassis potential.

70Vdc

Auxiliary Power Supply
Output Voltage

12Vdc

Maximum Current Source Capability

10mA

Remote inhibit function (I/O)
Use to disable the output of DC power supply; Active Low

TTL

DC-ON Output Signal
Indicate the output status; Active High

TTL

Fault output signal
Indicate if there is a fault/protection occurred; Active Low

TTL

Series & Parallel operation function with Master / Slave control
Voltage limit @ Series Mode

See Electrical Specification

Number of DC Power Supplies allowed @ Master / Slave control mode

5

Auto Sequencing Programmable Function
Number of program

10

Number of sequence

100

Time Range

5ms - 15,000S

TTL signal out

8 bits

TTL source capability

7 mA

Voltage Step Mode Programmable Function
Start Voltage Range

0~full scale

End Voltage Range

0~full scale

Total Run Time Range (hhh:mm:ss.sss)

10ms - 99 hours

Slew Rate Control Function
Voltage slew rate range

(The fall slew rate will be affected by the discharge rate of the output capacitors especially under no load condition.)

See Electrical Specification

Current slew rate range

See Electrical Specification

Minimum transition time.

0.5 ms

Remote Sense
Line loss compensation

5V

GENERAL SPECIFICATIONS

All specifications are subject to change without notice. Please visit our website for the most up to date specifications.

62000P-E-201207-2000

Worldwide Distribution

and Service Network

JAPAN

CHROMA JAPAN CORP.

472 Nippa-cho, Kouhoku-ku,

Yokohama-shi, Kanagawa,

223-0057 Japan

http://www.chroma.co.jp

E-mail: [email protected]

U.S.A.

CHROMA SYSTEMS

SOLUTIONS, INC.

25612 Commercentre Drive,

Lake Forest, CA 92630-8830

Tel: +1-949-600-6400

Fax: +1-949-600-6401

Toll Free: +1-866-600-6050

http://www.chromausa.com

E-mail: [email protected]

Developed and Manufactured by :

CHROMA ATE INC.

致茂電子股份有限公司

HEADQUARTERS

66 Hwaya 1st Rd., Kueishan

Hwaya Technology Park,

Taoyuan County 33383,

Taiwan

Tel: +886-3-327-9999

Fax: +886-3-327-8898

http://www.chromaate.com

E-mail: [email protected]

EUROPE

CHROMA ATE EUROPE B.V.

Morsestraat 32, 6716 AH Ede,

The Netherlands

Tel: +31-318-648282

Fax: +31-318-648288

http://www.chromaeu.com

E-mail: [email protected]

CHINA

CHROMA ELECTRONICS

(SHENZHEN) CO., LTD.

8F, No.4, Nanyou Tian An

Industrial Estate, Shenzhen,

China PC: 518052

Tel: +86-755-2664-4598

Fax: +86-755-2641-9620

Advertising