CONTROL METHOD FOR PARALLELED
Type A - Control with CSU
:
User can control via APG, CAN Bus/ Ethernet, and front panel manual control for paralleled operation.
Type B - Control without CSU
:
User can only control via CAN Bus for paralleled operation.
Note: The SoftPanel can control four mainframes for paralleled operation.
Type C - Control without CSU or PC
:
User can only control via remote on/off signal for paralleled operation.
Note 1 : User can NOT adjust the output voltage when parallel the output.
Note 2 : The output voltage will fixed in factory default voltage.
Note 3 : If need to adjust the output voltage, please adjust when stand alone.
Note 4 : Time delay from output enable until output stable: 10s max.
Front Panel Control
APG
CAN or Ethernet
CAN Bus
CAN Bus
PC
DUT
Parallel Output
Output
Output
CAN Bus
CAN Bus
PC
DUT
Parallel Output
Output
Output
Remote ON/OFF signal → DRY CONTACT〔Closed = enabled ; Open = disable〕
DUT
Parallel Output
Output
Output