CONTROL METHOD FOR PARALLELED

Type A - Control with CSU

:

User can control via APG, CAN Bus/ Ethernet, and front panel manual control for paralleled operation.

Type B - Control without CSU

:

User can only control via CAN Bus for paralleled operation.

Note: The SoftPanel can control four mainframes for paralleled operation.

Type C - Control without CSU or PC

:

User can only control via remote on/off signal for paralleled operation.

Note 1 : User can NOT adjust the output voltage when parallel the output.

Note 2 : The output voltage will fixed in factory default voltage.

Note 3 : If need to adjust the output voltage, please adjust when stand alone.
Note 4 : Time delay from output enable until output stable: 10s max.

Front Panel Control

APG

CAN or Ethernet

CAN Bus

CAN Bus

PC

DUT

Parallel Output

Output

Output

CAN Bus

CAN Bus

PC

DUT

Parallel Output

Output

Output

Remote ON/OFF signal → DRY CONTACT〔Closed = enabled ; Open = disable〕

DUT

Parallel Output

Output

Output