Agilent models: 6571A, 6572A, 6573A, 6574A, 6575A

425.5 mm

16.75"

574 mm

22.6"

640 mm

25.4"

68 mm

2.67"

132.6 mm

5.2"

145.1 mm

5.71"

12.7 mm

0.5"

128 mm

5.04"

Accepts wire

AWG 12-22

1/4" x 1" untreaded
hole on each bussbar

Note: Buss bar is 1/8" thick cu

1.25"

0.75"

0.31 dia"

1.0"

0.5"

IM
VP

+IP

-IP
+P
+S

-S

-LS

+LS

Top

Side

Rear

Rear connector detail

Buss bar detail

Supplemental characteristics
for all model numbers

DC floating voltage: Output terminals
can be floated up to ± 240 VDC from
chassis ground

Output common-mode noise current:
(to signal ground binding post)
500 μA rms, 4 mA peak-to-peak

Remote sensing: Up to half the rated
output voltage can be dropped in each
load lead. The drop in the load leads
subtracts from the voltage available
for the load.

Modulation: (Analog programming of
output voltage and current)
Input signal: 0 to –4 V for voltage,

0 to 7 V for current

Input impedance: 30 kΩ or greater

Input power: 3,800 VA, 2,600 W at full
load; 170 W at no load

Regulatory compliance: Listed to
UL1244; certified to CSA556B; conforms
to IEC 61010-1

Size:
425.5 mm W x 132.6 mm H x 640 mm D
(16.75 in x 5.22 in x 25.2 in)

Weight: Net, 28.2 kg (62 lb);
shipping, 31.8 kg (70 lb)

Warranty: One year