Supplemental Characteristics
for all model numbers

dc Floating Voltage: Output terminals
can be floated up to ±240 Vdc from

chassis ground

Output Common-Mode Noise Current:
(to signal ground binding post)

500 µ A rms, 4 mA peak-to-peak

Remote Sensing: Up to half the rated
output voltage can be dropped in each

load lead. The drop in the load leads

subtracts from the voltage available for

the load.

Command Processing Time: Average time
required for the output voltage to begin

to change following receipt of digital

data is 20 ms for the power supplies

connected directly to the GPIB.

Modulation: (Analog programming of
output voltage and current)

Input Signal:

0 to –4 V for voltage,

0 to 7 V for current

Input Impedance:

60 k Ohm or greater

Input Power: 3,800 VA, 2,600 W at full
load; 170 W at no load

GPIB Interface Capabilities: SH1, AH1, T6,
L4, SR1, RL1, PP0, DC1, DT1, E1, and C0.

IEEE-488.2 and SCPI-compatible

command set

Regulatory Compliance: Listed to UL1244;
certified to CSA556B; conforms to

IEC 61010-1.

Size: 425.5 mm W x 132.6 mm H x 640 mm D
(16.75 in x 5.22 in x 25.2 in)

See page 102 for more details

Weight: Net, 28.2 kg (62 lbs);
shipping, 31.8 kg (70 lbs)

Warranty Period: Three years

Single-Output: 2000 W GPIB

(Continued)

S p e c i f i c a t i o n s

(at 0

˚

to 55

˚

C unless

otherwise specified)

6671A-

6671A-

6671A-

6672A-

6673A-

J03

J04

J17

J04

J03

Special Order

Special Order

Special Order

Special Order

Special Order

Option

Option

Option

Option

Option

Number of outputs

1

1

1

1

1

GPIB

Yes

Yes

Yes

Yes

Yes

Output ratings

Output voltage

14 V

10 V

15 V

24 V

37.5 V

Output current

150 A

200 A

120 A

85 A

45 A

Programming accuracy at 25

˚

C ±5

˚

C

Voltage

0.04%+

14 mV

10 mV

15 mV

25 mV

37.5 mV

Current

0.1%+

90 mA

125 mA

90 mA

60 mA

40 mA

Ripple and noise

from 20 Hz to 20 MHz

Voltage rms

1.5 mV

750 µV

1.5 mV

1 mV

800 µV

Voltage peak to peak

15 mV

9 mV

15 mV

11 mV

9 mV

Current rms

150 mA

200 mA

150 mA

100 mA

40 mA

Readback accuracy at 25˚C ±5˚C
(percent of reading plus fixed)
System models only

Voltage

0.05% +

25 mV

15 mV

27 mV

40 mV

53.5 mV

±Current

0.1% +

110 mA

150 mA

110 mA

100 mA

60 mA

Load regulation

Voltage

0.002%+

600 µV

300 µV

650 µV

650 µV

1.2 mV

Line regulation

Current

0.005%+

7 mA

10 mA

7 mA

7 mA

4 mA

Transient response time

Less than 900 µs for the output voltage to recover 100 mV following a
change in load from 100% to 50% or 50% to 100% of the output current
rating of the supply

Supplemental Characteristics

(Non-warranted characteristics determined by design and
useful in applying the product)

Average resolution

Voltage

4 mV

2.5 mV

4 mV

6 mV

10 mV

Current

40 mA

55 mA

35 mA

22 mA

15 mA

OVP

28 mV

20 mV

30 mV

42 mV

65 mV

Output Voltage programming

response time*

(excluding command

30 ms

35 ms

35 ms

70 ms

130 ms

programming processing time)

*

Full load programming rise/fall time (10% to 90% or 90% to 10%) with full resistive load equal to rated output

voltage/rated output current.

Power Products Catalog 2002-2003

For more detailed specifications see the product manual at

www.agilent.com/find/power

Agilent Performance dc Power Supplies