Ordering Information

Opt 200 174 to 220 Vac, 47 to 63 Hz
(Japan only)

Opt 230 191 to 250 Vac, 47 to 63 Hz

* Opt 908 Rack-mount Kit (p/n 5062-3977)

* Opt 909 Rack-mount Kit w/handles

(p/n 5063-9221)

Opt 0L2 Extra Standard
Documentation Package

Opt 0B3 Service Manual

Opt 0B0 No documentation package

* Support rails required

Accessories

p/n 1494-0059 Accessory Slide Kit

p/n 1252-3698 7-pin Analog Plug

p/n 1252-1488 4-pin Digital Plug

p/n 5080-2148 Serial Link Cable
2 m (6.6 ft)

E3663AC Support rails for
Agilent rack cabinets

Single-Output: 2000 W GPIB

(Continued)

S p e c i f i c a t i o n s

(at 0

˚

to 55

˚

C unless

otherwise specified)

6673A-

6674A-

6674A-

6675A-

6675A-

J08

J03

J07

J04

J06

Special Order

Special Order

Special Order

Special Order

Special Order

Option

Option

Option

Option

Option

Number of outputs

1

1

1

1

1

GPIB

Yes

Yes

Yes

Yes

Yes

Output ratings

Output voltage

40 V

56 V

50 V

160 V

135 V

Output current

50 A

38 A

42 A

13 A

16 A

Programming accuracy at 25

˚

C ±5

˚

C

Voltage

0.04%+

40 mV

60 mV

60 mV

160 mV

125 mV

Current

0.1%+

35 mA

28 mA

30 mA

10 mA

12 mA

Ripple and noise

from 20 Hz to 20 MHz

Voltage rms

1 mV

1.25 mV

1.25 mV

2.8 mV

2 mV

Voltge peak to peak

10.5 mV

11 mV

11 mV

20 mV

18 mV

Current rms

40 mA

28 mA

25 mA

18 mA

12 mA

Readback accuracy at 25˚C ±5˚C
(percent of reading plus fixed)
System models only

Voltage

0.05%+

60 mV

90 mV

90 mV

240 mV

185 mV

±Current

0.1%+

60 mA

38 mA

42 mA

14 mA

18 mA

Load regulation

Voltage

0.002%+

1.4 mV

2 mV

2 mV

6 mV

4 mV

Line regulation

Current

0.005%+

4 mA

2 mA

2 mA

1 mA

4 mV

Transient response time

Less than 900 µs for the output voltage to recover 100 mV following a
change in load from 100% to 50% or 50% to 100% of the output current
rating of the supply

Supplemental Characteristics

(Non-warranted characteristics determined by design and
useful in applying the product)

Average resolution

Voltage

10.5 mV

14 mV

12 mV

40 mV

34 mV

Current

12.5 mA

9.5 mA

11 mA

3.25 mA

4 mA

OVP

75 mV

100 mV

85 mV

300 mV

242 mV

Output Voltage programming

response time*

(excluding command

130 ms

130 ms

130 ms

280 ms

250 ms

programming processing time)

*

Full load programming rise/fall time (10% to 90% or 90% to 10%) with full resistive load equal to rated output

voltage/rated output current.

Power Products Catalog 2002-2003

For more detailed specifications see the product manual at

www.agilent.com/find/power

Agilent Performance dc Power Supplies

speed and accuracy for test optimization

Advertising