Model selection chart, Common specifications, Output voltage ranges – Atec California-Instruments-6000L User Manual

Page 2: Total harmonic distortion, Line input, Output frequency, Ac noise level, Connectors, Protection

Advertising
background image

Model

Power

Phase

2

Current in 135 V range

Cur/phase

Size

Weight

at 35° C

1

A rms A peak

3

A peak

4

3ø mode

(H x W x D)

751L

833 VA

1

6.2

55.6

60

n/a

1501L

1667 VA

1

12.3

55.6

60

n/a

5.25” x 19” x 23”

85 lb

1503L

1667 VA

3

4.1

9.3

10

4.1

133 x 483 x 584 mm

38.3 Kg

2001L

2000 VA

1

14.8

55.6

60

n/a

2750L

3000 VA

1 or 3

22.2

83.3

90

7.4

10.5” x 19” x 23”

175 lb

4500L

5000 VA

1 or 3

37

83.3

90

12.3

267 x 483 x 584 mm

97.2 Kg

6000L

6000 VA

1 or 3

44.4

157.4

170

14.8

9000L

10000 VA

1 or 3

74

166.7

180

24.7

21” x 19” x 23”

350 lb

12000L 12000 VA

1 or 3

90

314.8

340

30.0

533 x 483 x 584 mm

158 Kg

13500L 15000 VA

1 or 3

111.2

250.0

270

37.0

31.5” x 19” x 23”

525 lb

18000L 18000 VA

1 or 3

133.2

472.0

510

44.4

800 x 483 x 584 mm

238 Kg

Notes: 1 Derate power by 10% for operation at 50° C ambient or when using the -UP option

3 Repetitive peak current capability

2 1 or 3 phase systems are factory configured unless the “MODE” option is specified

4 Non repetitive peak inrush current

Our broad range of models lets you choose the right power level for your application

The L-Series offers the ultimate in flexibility. Select the power level best suited to your requirements. Then

select the controller that provides the functions important to you. Complete your selection by choosing from

the L-Series’ comprehensive list of options, and you have a truly custom solution at an “off-the-shelf” price.

All L-Series Models Conform to These Specifications:

Output Voltage Ranges

Standard:

0-135 V, L-N
0-270 V, L-N

-HV Option:

0-156 V, L-N
0-312 V, L-N

-LV Option:

0-67.5 V, L-N
0-135 V, L-N

-EHV Option:

0-200 V, L-N
0-400 V, L-N

Total Harmonic Distortion

45 Hz to 2 kHz: 1 percent
To 5 kHz:

2 percent

50/60 Hz:

0.5 percent typical

Line Input

Models 751L, 1501L, 1503L,
2001L:

115 V or 230 V single phase
47 Hz to 440 Hz

Models 2750L, 4500L, 6000L,
9000L, 12000L, 13500L, 18000L:

187 V - 252 V, L-L, 3 phase
(342 V - 456 V, L-L, 3 phase with
-UP option, except 6000L,
12000L and 18000L)

2750L: 1 or 3 phase input 187 -

252 V

Output Frequency

See V-F derating for 17 Hz to 45
Hz performance
Models 751L, 1501L, 1503L,
2001L, 2750L-3, 4500L-3 and
6000L-3:
17 Hz to 5 kHz
Models 2750L-1, 4500L-1, 9000L
and 13500L:
17 Hz to 2 kHz
Models 6000L-1, 12000L and
18000L:
17 Hz to 440 Hz
All models with -PT controller:
17 Hz to 550 Hz except 6000L,
12000L and 18000L

AC Noise Level

160 mV rms typical

Connectors

n

n

Input provided on rear terminal
block

n

n

Output provided on rear
terminal block (Remote sense

mating connectors are provided)

Protection

n

n

Overcurrent

n

n

Overpower

n

n

Short circuit

n

n

Overtemperature

n

n

Current limit trip standard with

programmable units. All units
have adjustable current limit.

Rating Curves

Advertising
This manual is related to the following products: