Controllers – Atec California-Instruments-6000L User Manual
Page 3

Three Different Controllers Offer Programmability Choices
1
Specification
Programmable -P
Programmable -PT
Manual -M
Controller Type
Programmable controller
Fast Transient controller
Manual control oscillator
Voltage
Range
0 - 135 V / 0 - 270 V L-N
0 - 135 V / 0 - 270 V L-N
Variable pot control
Programmable range change
Programmable range change
Switchable range change
Individual phase programming
Individual phase programming
Option -RPV for 0-FS control
using 0 - 10 VDC input.
Accuracy
± 0.135V from 5 V to 135 V
± 0.7 % FS from 5 % to FS
Variable control
± 0.54 V from 135 V to 270 V
Constant line, load and
Analog meter readback
@ 25° C ± 1° C
temperature @ 25° C ± 1° C
Load Regulation
TRMS Sense: ± 0.05 % FS
- 0.5 % FS from 45 Hz to 100 Hz
± 0.05 % from 45 Hz to 5 kHz
no load to full load
- 2 % FS from 100 Hz to 550 Hz
Line Regulation
± 0.02 % FS for ± 10 %
± 2 % of full output for
± 0.02 % of full output for
line change
a ± 10 % line change
a ± 10 % line change
Stability
± 0.015 % FS over 24 hours at
± 0.25 % FS over 24 hours at
± 0.015 % FS over 24 hours at
constant line, load and temperature
constant line, load and temperature
constant line, load and temperature
Initial value
0.0 or 5.0 Vrms field selectable
0 Vrms
N/A
Settling time
16 msec, no-load from
0.5 msec
N/A
5 V to within 2 % of final value;
16 msec, full load from
5 V to within 15 % of final value
Programmable THD
N/A
0 - 20 % THD clipped sine
N/A
1 % resolution
Amplitude Modulation
N/A
0 to 5 V RMS generates 0 to 11 %
0 to 5 V RMS generates 0 to 11 %
amplitude modulation of output
amplitude modulation of output
voltage. 45 Hz to 5 kHz input
voltage.
Frequency
Range
2750L-1P, 4500L-1P
6000L, 12000L and 18000L:
2750L-1M, 4500L-1M
and all multibox systems:
45 to 440 Hz
and all multibox systems:
45 Hz to 2 kHz
All other models:
45 Hz to 2 kHz
-3P and 751L - 2001L:
45 Hz to 550 Hz
-3M and 751L - 2001L:
45 Hz to 5 kHz
45 Hz to 5 kHz
6000L, 12000L and 18000L:
6000L, 12000L and 18000L:
45 Hz to 440 Hz
45 Hz to 440 Hz
Resolution
0.01 Hz; 45.00 Hz to 99.99 Hz
0.01 Hz; 45.00 Hz to 99.99 Hz
3 digits
0.1 Hz; 100.0 Hz to 999.9 Hz
0.1 Hz; 100.0 Hz to 550.0 Hz
1 Hz; 1000 Hz to 5000 Hz
Accuracy
± 0.001 % of programmed value
± 0.001 % of programmed value
± 0.005 % of set value
Initial value
Any within range
Any within range
Setting
External Sync Input
TTL level
TTL level
N/A
Phase
Range
Phase B and/or C relative to
Phase B and/or C relative to
N/A
phase A: 0 to ± 360° in 0.1°
phase A: 0 to ± 360° in 0.1°
increments
increments
Accuracy
± 2 °
± 2 °
± 3 °
Current
Programmable Limit
Adjustable trip
Adjustable trip
Adjustable foldback with
recovery
Remote Inhibit
Contact closure turns
Contact closure trips unit
Contact closure turns
output off
off. Sets defaults.
output off
Measurements
Voltage
resolution 0.1 Volt, accuracy ± 10 digits
N/A
Current
resolution 0.01 Amp or 0.1 Amp, accuracy ± 10 digits
N/A
Power
resolution 1 W or 0.01 kW, accuracy ± 10 digits
N/A
Phase angle
resolution 0.1°, accuracy ± 2° to 2 kHz, ± 3° to 5 kHz
N/A
Power Factor
range 0.000 to 0.001
N/A
Frequency
resolution four decades, accuracy ± 0,02 Hz to 99.99 Hz,
N/A
± 0.2 Hz to 500.0 Hz, ± 0.5 Hz to 999.9 Hz, ± 10 Hz to 5 kHz
Apparent Power
resolution 1 VA or 0.01 kVA, accuracy ± 10 digits
N/A
Note 1
One of these three controller types must be specified when ordering a L Series power source or, for Arbitrary waveform generation,
refer to the HGA controller.