Eries, Pecifications, Specifications – Atec Elgar-501b User Manual

Page 2: Single phase output power, Model power output input physical comments

Advertising
background image

Elgar

1.800.733.5427

858.450.0085

Fax 858.458.0267

9250 Brown Deer Road, San Diego, CA 92121

www.elgar.com

email: [email protected]

21

SL

AND

B S

ERIES

S

PECIFICATIONS

SPECIFICATIONS

OUTPUT
Voltage Range:
SL Series: 0-65, 0-130,
0-260 VAC; B Series: 0-32, 0-65, 0-130,
0-260 VAC (varies per model). Specific
output range is selected by jumper change
on rear panel. Consult Elgar for other voltage
ranges.

Rated Power Voltage Range: Full rated
VA from 55-65 VAC, 110-130 VAC, or
220-260 VAC over a ±10% input and rated
PF range

SL Series: Continuous duty at 150% of
rated capacity at 55C°*

B Series: Continuous duty at 100% of
rated capacity*

Load Power Factor: Unity to ±0.7 PF at
rated VA with an output voltage
adjustment range of 85-100% of full scale*

Frequency Range: 45 Hz to 5 kHz at full
rated power

Total Harmonic Distortion:
SL Series:
0.4% 200 Hz to 1000 Hz

0.6% Full frequency range

B Series: 0.5% 100 Hz to 1000 Hz

0.9% Full frequency range

Load Regulation: ±1% no load to full
load over full frequency range. Better than
±0.25% for fixed frequency output.
Adjustable to ±0.1% for specific load
conditions and to ±0.015% with a PIP

Line Regulation: ±0.25% at rated load
for a ±10% input change at full scale
output voltage

Response Time: < 50 microseconds

AC Noise Level: 70 dB below full output
voltage with input grounded

INPUT
Voltage SL Series:
See model number
description on page 23.

Three Phase B Series Models: See table

Frequency: 47 to 63 Hz (400 Hz option,
special order)

Efficiency: Up to 45%

GENERAL

Operating Temperature Range: 0° to
+55°C

Operating Humidity Range: Up to 95%
non-condensing

Metering: SL Series: 0-300 VAC output
voltmeter, ±3% accuracy
B Series: 0-150 VAC

Controls: Input power switch/circuit
breaker and pilot light. Full range, 10-turn
output voltage control potentiometer

*See Power Rating Curve on page 23.

Single Phase Output Power

Model

Power

Output

Input

Physical

Comments

Total VA

Vol. Range

Max Current

Frequency

Voltage and Nominal/Max

Height and Depth

Weight WT

(RMS)L-N

(RMS)

1

Range (Hz)

Phase

(kVA)

2

(in/mm) (lbs/kg)

121B

120

0-130

1.1

45 to 5k

115 or 230, 1ø

0.4 3.5/89

H

47/21

Net

0-32V/4.4A

range

available;

0-260

0.55 5/127

D

51/23

Ship

Model

121B-101

251B

250

0-32

9.2

45 to 5k

115 or 230, 1ø

0.8 5.25/133

H

49/22

Net

0-130 2.25

16/405

D

55/25

Ship

0-260

1.1

351 SL-XX

350

0-65

8.0

45 to 5k

115 or 230, 1ø

1.0/1.6

5.25/133 H

75/34

Net

0-130

4.0 21/533

D

83/38

Ship

0-260 2.0

501 SL-XX

500

0-65

11.5

45 to 5k

115 or 230, 1ø 1.5/2.2

5.25/133

H 80/36

Net

0-130 5.8

21/533 D

88/40

Ship

0-260 2.9

751 SL-XX

750

0-65

17.3

45 to 5k

115, 208 or

2.2/3.2

7.00/178

H

115/52

Net

0-130 8.65

230,

21/533

D 25/57

Ship

0-260

4.3

1001 SL-XX

1000

0-65

23.1

45 to 5k

115, 208 or

3.0/4.2

7.00/178

H

125/57

Net

&

0-130 11.5

230,

21/533 D

135/61

Ship

1001 SLE-2X

0-260 5.8

1001 SLE-21 only

1751 SL-XX

1750

0-65

40.4

45 to 5k

115, 208 or

5.2/7.5

12.25/311

H

190/86

Net

&

0-130 20.2

230,

21/533

D 200/91

Ship

1751 SLE-2X

0-260 10.1

1751 SLE-21 only

3001

3000

0-65

54.5

45to 3k

208 or 416

9.0

17.5/445

H

315/143

Net

0-130 27.2

L-L,

3

ø

22/560

D 361/164 Ship

0-260 13.6

3500 SL-XX

3500

0-65

80.8

45 to 5k

115, 208

10.5/15.0

24.50/622

H

380/172

Net

2ea 1751 SL, 1 ea 400 SR,

&

0-130

40.4

or 230, 1ø

21/533 D

400/182

Ship

1ea signal

cable

3500 SLE-2X

0-260

20.2

3500 SLE-21 only

6000-1

6000

0-130

54.5

45 to 3k

208 or 416,

18.0

35/890

H

630/286

Net

2ea 3001 (Series)1ea 400 SR

0-260

27.2 L-L,

3ø 22/560

D

722/328

Ship

1ea signal

cable

0-520 13.6

9000-1

9000

0-130

81.8

45 to 3k

208 or 416,

27.0

52.5/1335

H

945/429

Net

3ea 3001-165A (parallel)

0-260 40.9

L-L,

22/560

D

1083/492

Ship

2ea 400 SR, 1ea signal cable

1

All SL models are specified at 150% of normal output current into a linear resistive load

2

SL models show value in kVA for both nominal and 150% load

Advertising