ENVIRONMENTAL DATA

Operating Temperature: 0°C to 45°C (32°F to 113°F)
Storage Temperature: -40°C to 70°C (-40°F to 158°F)
Humidity (Non-condensing): 0 to 85% at 25°C (77°F);
derate to 50% at 40°C (104°F)

Altitude: Operating 10,000 ft, non operating 40,000 ft

SMARTWAVE

TM

(SW)

SPECIFICATIONS CONTINUED AND MODEL NUMBERING

ORDERING INFORMATION

MODEL NUMBER

OUTPUT POWER RATING

AC INPUT

POWER FACTOR

CORRECTION (PFC)

SW 1750A-1

1750 VA

1

187-264 VRMS (L-L), 3-wire

NO

SW 1750A-2

1750 VA

1

342-457 VRMS (L-L), 4-wire

NO

SW 1750A-3

1750 VA

1

187-264 VRMS (L-L), 3-wire

YES

SW 1750A-4

1750 VA

1

342-457 VRMS (L-L), 4-wire

YES

SW 3500A-1

3500 VA

2

187-264 VRMS (L-L), 3-wire

NO

SW 3500A-2

3500 VA

2

342-457 VRMS (L-L), 4-wire

NO

SW 3500A-3

3500 VA

2

187-264 VRMS (L-L), 3-wire

YES

SW 3500A-4

3500 VA

2

342-457 VRMS (L-L), 4-wire

YES

SW 5250A-1

5250 VA

3

187-264 VRMS (L-L), 3-wire

NO

SW 5250A-1

5250 VA

3

342-457 VRMS (L-L), 4-wire

NO

SW 5250A-1

5250 VA

3

187-264 VRMS (L-L), 3-wire

YES

SW 5250A-1

5250 VA

3

342-457 VRMS (L-L), 4-wire

YES

1

1495 VA at 115V or 230V output

2

2990 VA at 115V or 230V output

3

4485 VA at 115V or 230V output

OPTIONS

• Measurement capability

• Input power factor correction to

0.99

• 16A/phase output

• Parallelable for additional power

from 10.5 kVA to 21 kVA

• External waveform creation

software DSP2

• 5V or 26V, 0.25A auxiliary AC

outputs

• Custom cabinets for 10.5, 15.75

& 21 kVA systems

• Interharmonic waveform

generator

• Low speed fan option

OTHER STANDARD FEATURES

• 1ø to 3ø programmable

• IEEE-488.2 interface

• SCPI protocol

• WaveForm trigger output: (1 MΩ Load

Drive)

• BNC outputs for scope viewing of

waveforms (1 MΩ Load Drive)

• SYNC OUT. User programmed for: Cycle

start, all cycles. Segment start, all or
selected segments. For loads ≥ 2 kΩ: V
out ≤ 1V low state; V out ≥ 2.4V high
state

• External Amplitude Modulation

0 to 5 VRMS provides 0 to ≥ 20% output
amplitude modulation

• Clock/lock:

Clock - pulses at programmed frequency.
For loads ≥ 2 kΩ V out: ≤ 1V low state; V
out ≥ 2.4V high state
Lock - locks output to input ‘TTL’ frequency;
signal needs to supply pull down current of
15 mA with voltage drop of ≤ 0.6V; no pull
up needed

• External Drive: Normal amplifi er, 0 to 5

VRMS (DC to 5 kHz) or ±5 VDC input for
zero to full voltage output

• External Gain Control: 0 to ±7.07 VDC

provides zero to full output

• External Input Impedance ≥ 30 kΩ