Atec Kepco-BOP-1 Series User Manual

Page 4

Advertising
background image

BOP 1KW ALLOW FOR AUTOMATIC
CREATION AND DISPLAY OF VARIOUS
WAVEFORMS AND COMPLEX PATTERNS

The 1000-watt models have an internal waveform generator
that allows a user to combine segments of a sinusoidal
waveform, triangular waveform, a ramp, a saw tooth
waveform and a square 50% duty cycle pulse, plus d-c to
create a variety of arbitrary waveforms. 3,933 of points per
basic waveform can be programmed with arbitrary phase
relationships. The resulting waveshape can be repeated
from 1 to 255 times. The waveshape can also be executed
indefinitely until a stop command is received. The wave-
shape graphics are displayed on the front panel-mounted
LCD display, which also shows both settings and actual d-c
output values. The programmed waveshapes can be used
to control either voltage or current with both positive and
negative values. It is possible to reproduce an a-c sinusoid
with differing degrees of distortion or dropouts for test
purposes. Alternatively, varying amounts of “noise” can be
added to a d-c output to gauge the effect on a test subject.

Sine Waveform

Triangle Waveform

Complex Sine Waveform

KEPCO, INC. • 131-38 Sanford Avenue • Flushing, NY 11355 USA • Tel: (718) 461-7000 • Fax: (718) 767-1102

Email: [email protected]www.kepcopower.com

For full specs, visit our Web site at www.kepcopower.com/bophi.htm

BOP 1KW OUTPUT CHARACTERISTICS

SPECIFICATIONS

RATING/DESCRIPTION

CONDITION

Type of Stabilizer

Voltage/Current 4-quadrant

Switch mode

Output stage

Switching Frequency

Voltage Stabilization
in
Voltage
Mode

Source
Adjustment
Range

100KHz ±5%

-100% to +100% of rating

-100% to +100% of rating

0-50°C

voltage

current

Sink
Adjustment
Range

-100% to +100% of rating

-100% to +100% of rating

0-50°C,

recuperated energy is

sent back into line for

general reuse

voltage

current

0.05% of rating

0.1% of rating

0.02% of rating

0.02%/°C of rating

2% Eomax p-p

0.2% Eomax rms

min-max

input voltage

0-100% load current

0.5 - 8 hours

0-50°C

Includes switching

noise

source effect

load effect

time effect (drift)

temperature effect

ripple

noise

Current Stabilization
in
Current
Mode

0.05% of rating

0.2% of rating

0.02% of rating

0.02%/°C of rating

2% Iomax p-p

0.2% Iomax rms

min-max

input voltage

0-100% load current

0.5 - 8 hours

0-50°C

Includes switching

noise

source effect

load effect

time effect (drift)

temperature effect

ripple

noise

Error Sensing

0.25 volts per wire

Above rated output

Output Common
Mode Voltage

Series Operation

Output Protection Limiting

Output Stage
Protection

300V

Master/slave

Voltage and current

limited in four quadrants

Output overvoltage/

overcurrent,

heat sink overtemperature,

switchers overcurrent

Input Stage
Protection
(PFC)

Internal overvoltage,

undervoltage, overcurrent,

heat sink overtemperature,

fan inoperative

Triggers latched

shutdown protection

of the output module

and PFC stage.

Recover by cycling

power off, then on or

by pressing RESET

at the front panel

Maximum of

3 identical units,

up to 300V max.

Parallel Operation

Master/slave

Output to chassis

ground

Transient
Recovery in
Voltage Mode

5% of nominal output

nominal voltage,

50% load step

maximum

excursion

200 μsec

Return within 0.1%

of set voltage

recovery

time

Maximum of

5 identical units

Input circuit breaker

overcurrent

Trips circuit breaker to

shut off unit

Small
Signal
Bandwidth

2 KHz maximum

voltage channel

800 Hz maximum

(600 Hz Maximum)

(1)

current channel

Rise/Fall
Time

250/200 μsec

voltage channel

0.7/1.2 mSec

current channel

Into short circuit

Into nominal

resistive load

Into short circuit

Into nominal

resistive load

4

(1) BOP 6-125MG only.

Advertising