3060-ms, True advantages – Atec Pacific-Power-3060MS User Manual

Page 2

Advertising
background image

3

060-MS

12"/ 305

mm

Input

Conduit

Output

Conduit

Exhaust Air

Knockouts for

Paralleling and Options

36"/ 914

mm

72"

1829

30"

762 mm

Air Intake

Air Intake

Input Circuit

FRONT

SIDE

TOP

© 2012 Pacific Power Source, Inc. Specifications subject to change without notice.

DS#43060MS122012

Page 2 of 4

350 Amps of Pulse Current

per phase

is delivered by

each 3060-MS for driving non-linear loads. This elimi-

nates the need to oversize facility power as is common

for rotary or low quality PWM power systems.

Load Power Factor

is not an issue. The 3060-MS will

drive virtually any load without damage or risk.

Excellent Regulation

and response time eliminates load

“cross talk.” Voltage sags common to other conversion

methods are eliminated with 150 microsecond re-

sponse time to a 50% load step. The output recovers to

± 3% of nominal within less than 1/10th of a cycle at

400 Hz.

Rugged, Powerful Output

Each 3060-MS

is capable of operating as either the mas-

ter or slave in a multi-cabinet parallel system providing

configuration flexibility.

Mission Reliability

is ensured. The parallel system ar-

chitecture is such that a failed slave unit automatically

removes itself from the power grid. Should the master

unit fail, the operator can select any other paralleled

unit as the new master from the front panel and restore

system operation.

Maximum Reliability

Lower Maintenance Costs

are achieved through

built-in diagnostics that minimize MTTR. Quick and

easy repair is facilitated with a small complement of

local spares.

Input Power Factor

is a constant 0.9 lagging, regard-

less of load. The MS Series actually corrects PF re-

flected back to the utility, eliminating PF penalties.

Low Installation Cost.

The MS Series fits through

standard doorways. Audible noise is limited to cool-

ing fans. There is no 400 Hz whine that requires

noise isolation. Solid state design with a forklift base

eliminates the need for concrete pads and vibration

isolators common to rotary installations. Casters are

optional if desired.

Low Cost of Ownership

True Advantages

Solid State Technology

Facility/Test Power Flexibility

Power Levels Grow

with demand. Units may be add-

ed or removed from the power grid as required.

Variable Frequency

range of 47–500 Hz, as well as

switch selectable fixed frequency operation of 50,

60 or 400 Hz, is standard on every model.

External Input

is provided as a standard feature. This

allows operation as a variable frequency test power

amplifier.

UPC-32 Programmable Controller Option

is avail-

able to provide steady state and transient control of

output power from the RS-232 or GPIB bus.

Measures

volts, amps, watts and kVA for each input and

output phase.

Efficiency

is continuously monitored, allowing system

performance verification.

• Internal Diagnostics assist in quickly locating failed

components, resulting in extremely low MTTR.

Power Generation

circuits are separate from display and

diagnostics. A failure in the display logic will not affect

output power quality. Output power cannot be inter-

rupted by system interrogation.

Audible and Visual Alarms

alert the operator to any con-

ditions requiring attention.

Simple / Informative Display