Email: [email protected]www.kepcopower.com

Model EL 1K-200-100D

Model EL 2K-200-200

SERIES EL MODEL TABLE

OPERATING LIMITS

OVERLOAD PROTECTION

RATED POWER

Watts

RATED VOLTAGE

Volts

RATED CURRENT

ALL MODES

Amps

POWER

(3)

Watts

VOLTAGE

(3)

Volts

CURRENT

(4)

Amps

MINIMUM ON

RESISTANCE

ALL MODES

Ohms

MODEL NUMBER

(1)(2)

EL 1K-50-125

(5)

EL 1K-200-100

(5)

EL 1K-400-70

(5)

EL 1K-600-30

(5)

EL 2K-50-250

(5)

EL 2K-200-200

(5)

EL 2K-400-140

(5)

EL 2K-600-60

(5)

EL 3K-50-400

EL 3K-200-300

EL 3K-400-210

EL 3K-600-90

EL 4K-50-600

EL 4K-200-500

EL 4K-400-350

EL 4K-600-150

EL 5K-50-800

EL 5K-200-600

EL 5K-400-420

EL 5K-600-200

1000

1000

1000

1000

2000

2000

2000

2000

3000

3000

3000

3000

4000

4000

4000

4000

5000

5000

5000

5000

50

200

400

600

50

200

400

600

50

200

400

600

50

200

400

600

50

200

400

600

125

100

70

30

250

200

140

60

400

300

210

90

600

500

350

150

800

600

420

200

1050

1050

1050

1050

2100

2100

2100

2100

3150

3150

3150

3150

525

2100

4200

4200

5250

5250

5250

5250

52.5

210

420

630

52.5

210

420

630

52.5

210

420

630

52.5

210

420

630

52.5

210

420

630

135

105

73.5

31.5

265

210

147

63

420

315

220.5

94.5

630

525

367.5

157.5

835

630

441

210

0.006

0.014

0.046

0.017

0.004

0.007

0.023

0.083

0.0035

0.005

0.015

0.056

0.002

0.003

0.009

0.033

0.002

0.002

0.008

0.028

INPUT

IMPEDENCE

Ohms

80K

160K

200K

320K

80K

160K

200K

320K

80K

160K

200K

320K

80K

160K

200K

320K

80K

160K

200K

320K

(1) For GPIB interface, add suffix "G" to the model number. The GPIB interface is in addition to the standard rS-232 and uSB interfaces, except for dual channel

models the GPIB interface replaces the standard rS-232 and uSB interfaces.

(2) For Ethernet interface (in addition to the standard rS-232 and uSB interfaces), add suffix "E" to the model number.
(3) Maximum operating power and/or current may be reduced when ambient temperature exceeds 35°C depending on air flow, duty cycle of load operation and

other situational specific conditions.

(4) Each FET is individually fused. Blown fuses are reported in unit status.
(5) For dual channel models (these models include two completely independent loads in a single chassis) add suffix "D" to the model number. Specifications listed