Output : Voltage and Current

Models

15-20

30-10

60-5

Output Ratings

Output Voltage

0-15 V

0-30 V

0-60 V

Output Current

0-20 A

0-10 A

0-5 A

Output Power

300 W

300 W

300 W

Line Regulation

2

Voltage (0.01% of Vmax + 2 mV)

3.5 mV

5 mV

8 mV

Current (0.05% of Imax + 2 mA)

12 mA

7 mA

4.5 mA

Load Regulation

3

Voltage (0.01% of Vmax + 2 mV)

3.5 mV

5 mV

8 mV

Current (0.05% of Imax + 2 mA)

12 mA

7 mA

4.5 mA

Meter Accuracy

Voltage (1% of Vmax + 1 count)

250 mV

400 mV

700 mV

Current (1% of Imax + 1 count)

300 mA

200 mA

60 mA

Output Noise (90-20 MHz)

Voltage (p-p) (0-20 MHz) rear panel

75 mV

75 mV

100 mV

Voltage (p-p) (0-20 MHz) front panel

100 mV

100 mV

180 mV

Output Ripple

Voltage rms, rear panel

5 mV

5 mV

5 mV

Voltage rms, front panel

10 mV

10 mV

10 mV

Drift (8 hours)

4

Voltage (0.02% of Vmax)

3 mV

6 mV

12 mV

Current (0.08% of Imax)

16 mA

8 mA

4 mA

Temperature Coefficient

5

Voltage (0.015% of Vmax/°C)

2.25 mV

4.5 mV

9 mV

Current (0.02% of Imax/°C)

4 mA

2 mA

1 mA

Specifications subject to change without notice.
1. Specifications indicate typical performance at 25°C ± 5°C, nominal line input of 120 Vac.
2. For input voltage variation over the AC input voltage range, with constant rated load.
3. For 0-100% load variation, with constant nominal line voltage.
4. Maximum drift over 8 hours with constant line, load, and temperature, after 60-minute warm-up.
5. Change in output per °C change in ambient temperature, with constant line and load.
6. Apply accuracy specifications according to the following voltage program accuracy example: Set a model 15-20 power supply to 10 V. The expected result will be within the
range of 10 V ± 60 mV ± 0.1% of the set voltage of 10 V.

HPD Series : Product Specifications

1

HPD 300 W Internal Interface Specifications with RS-232 or GPIB Interface Installed

1,6

Models

15-20

30-10

60-5

Program Accuracy

Voltage (mV)

60 + 0.1%

70 + 0.1%

90 + 0.12%

Current (mA)

75 + 0.12%

50 + 0.12%

25 + 0.1%

OVP (mV)

1500

3000

6000

Readback Accuracy

Voltage (mV)

45 + 0.3%

90 + 0.3%

175 + 0.3%

Current (mA)

75 + 0.12%

40 + 0.12%

25 + 0.1%

108