Utput, Constant voltage mode, Constant current mode – Atec Sorensen-PRO-T Series User Manual

Page 2: Nput, Eneral, Ptions, Ccessories, Input voltage options, Pro-t accessories

Advertising
background image

24

Sorensen • 858/450-0085 • 800/733-5427 • Fax: 858/458-0267 • 9250 Brown Deer Road • San Diego • California • 92121-2294 • www.elgar.com • E-mail: [email protected]

O

UTPUT

Voltage:

See table

Current:

See table

Constant Voltage Mode

Noise and Ripple:

See table

Regulation
Line and Load Combined:

0.1% of the

voltage setting or specification in table,
whichever is greater

Transient Response:

Typically recovers in

40 ms to within 1% of steady-state output
voltage for a 50% to 100% or 100% to 50%
load change

Stability:

0.1% of maximum voltage over

8 hours after 30 minute warm up time at
fixed line, load and temperature

Temperature Coefficient:

0.02%/°C of

maximum output voltage

Constant Current Mode

Ripple:

See table

Regulation
Line and Load Combined:

0.1% I

0

max. of

the output current setting or specification in
table, whichever is greater

Stability:

0.1% of maximum current over 8

hours after 30 minute warm-up time at fixed
line, load and temperature

Temperature Coefficient:

0.04%/°C of

maximum output current

I

NPUT

Voltage and Frequency:

480 VAC ± 10%,

50-60 Hz, three phase

Voltage Options:

See Input Voltage Options

Current:

See table

G

ENERAL

Operating Temperature:

0° to 50°C

(derated above 30°C)

Storage Temperature:

-45°C to 85°C

Cooling:

Forced air, fan cooled

Humidity Range:

0-90% RH,

non condensing

Efficiency:

80% at full rated output (typical)

Series Operation:

200 VDC max.; consult

Sorensen for series operation of more than
2 units

Parallel Operation:

Master/slave operation

up to 3 units. Consult factory for details.

Overvoltage Protection:

Adjustable

5-110% of rated output. Selectable front
panel or remotely programmable

Meter Accuracy:

1% of full scale + 1 count

Voltage Programming:

100 mV per 1% of

rated output (0-10 V for 0-100% of rated
output)

Current Programming:

100 mV per 1% of

rated output. (0-10V for 0-100% of rated
output)

Resistive Programming:

100

Ω per 1% of

rated output (0-10 k

Ω for 0-100% of rated

output)

Remote Sense:

5V max. drop in

(+) power lead or (-) power lead

Software:

LabVIEW® driver for M9C/M85,

programs can be downloaded at no cost at
www.sorensen.com/support/downloads.cfm

Regulatory Compliance:

CE Mark

(<300V models only)

Dimensions:

7U or 12.25” (311 mm) H x

19” (482 mm) W x 24” (609 mm) D

Weight:

310 lbs. (141 kg)

Shipping Weight:

380 lbs. (172 kg)

O

PTIONS

& A

CCESSORIES

M5:

SCR crowbar

M9C:

Internal IEEE-488/RS 232 Interface

M36:

CE Mark (<300V models only)

M85:

Multichannel slave interface

M86:

Parallel cable

Input Voltage Options

Specifying Note: Select AC input voltage option

below and add as a part number suffix to specify

power supplies (listed as 50-60 Hz, three phase)

T1:

208 VAC

T5:

480 VAC

T2:

380 VAC

T8:

220 VAC

T3:

415 VAC

T10:

230 VAC

T4:

440 VAC

T11:

400 VAC

PRO-T Accessories

Caster Cart Kit:

Part No. 1064395-1

Advertising