26

Options & Accessories

* Specifying Note: Select AC input voltage option

Side View

Front View

Rear View

Dimensions in inches (millimeters)

Note 1: 300V and 600V units provided with 1” long x 5/16” threaded output studs in place of buss bars

and add as a part number suffix to specify

power supplies (listed as 50-60 Hz, three phase)

Accessories

M5

SCR Crowbar

M9C Internal IEEE-488/RS 232 Interface

M36 CE Mark

Input Voltage Options*

T1

208 VAC

T2

380 VAC

T3

415 VAC

T4

440 VAC

T5

480 VAC

T8

220 VAC

T10 230 VAC

M85 Multichannel Slave Interface

T11 400 VAC

Remote Interface Options

Accessories

Regulatory Compliance

M86 Parallel Cable

M5A: J-305 Pin Assignments

1

Overvoltage Protection Flag

14

2
3
4
5
6
7
8
9

10

11

12

16

Not Used

TTL Shutdown Return

15

TTL Shutdown

Not Used

Current Limit Program

Program Return

17

Voltage Program

Program Return

18

Current Readback

Auxiliary Ground

19

Voltage Readback

Remote Voltage Program Select*

20

+10V Reference Out (10 mA max.)

Remote Current Program Select*

21

Output Fail Flag*

Voltage Current Limit Mode Indicator

22

+ Sense

+ Out

23

+ Out

+ Out

24

- Return

- Return

25

- Return Sense

13

- Return

Advertising