Asd series : product specifications – Atec Sorensen_ASD Series User Manual

Page 2

Advertising
background image

www.ProgrammablePower.com

Output

Voltage Output

10kW

20kW

30kW

Noise (pk-pk)***

Noise (RMS)***

40Vdc

250A

500A

750A

150mV

40mV

60Vdc

167A

334A

501A

150mV

40mV

(*) Measured at the load terminals, with 1uF in parallel and 6ft of low-inductance load cable with supply operating at full load and nominal input line voltage.
(**) RMS noise is measured directly across the output terminal with supply operating at full load and nominal input line voltage.
(***) Value is for 30kW, single voltage models. Other variations may increase value by 2x.

Sense

To compensate load cables voltage drop, units can generate 2% additional voltage at full scale of output voltage.

ASD Series : Product Specifications

Input

Type: 3-phase, 3-wire plus ground, neutral not required. Not phase rotation sensitive

Voltage Ranges

342VAC to 440VAC (model D). Nominal rating is 380/400VAC.
432VAC to 528VAC (model E). Nominal rating is 480VAC

Frequency

Rated 47 through 63 Hz

Efficiency

>91% (typical), nominal line, full load.

Max Current, per phase, low line

400/380Vac

480Vac

10kW unit (1 module)

21Arms

17Arms

20kW unit (2 modules)

42Arms

33Arms

30kW unit (3 modules)

63Arms

50Arms

Current Inrush

200A Typical

Power Factor

>0.9 @ Full Load and at nominal line

Brownout Provisions

Designed to meet SEMI F47-0706, S3, S8, S14 at nominal input voltages

Output

Load Regulation (Specified at No load to Full load change, nominal AC input)

Voltage

0.1% of maximum output voltage/ current

Current

0.1% of maximum output voltage/ current

Line Regulation (Specified at ±10% of nominal AC input, constant load)

Voltage

0.05% of maximum output voltage/ current

Current

0.05% of maximum output voltage/ current

Transient Response

A 50% step load will recover to within 0.75% of original value within 1mSec

Stability

±0.05% of set point after 8 hrs. at fixed line, load and temperature. After 30min warm-up.

Analog Remote Programming

Voltage Accuracy

0.5% of full scale

Current Accuracy

1% of full scale

Power Accuracy

1.5% of full scale

Voltage Monitoring

0.5% of full scale

Current Monitoring

1% of full scale

Power Monitoring

1.5% of full scale

Programming range

0-10Vdc, 4-20mA

Output

Output Float

Units maybe put in series with the float limit of output terminals must be within ±150V of chassis potential

Parallel

Multiple units can be paralleled to form higher power systems. Chassis control loops are tied together so that resulting higher
power systems have the same transient response as a 30kW system. Control commands are only required to be sent to “master”
supply. Parallel supplies require a shielded CAT 5 cable (STP) and appropriate output wiring connections by the user.

Calibration

End user calibration is supported. All standard and digital calibration can be performed without removing covers.

Digital Control (Optional)

Ethernet (Modbus-TCP or Ethernet/IP), RS-485 (MODBUS-RTU)

Analog Control

All control signals are isolated from the outputs