OPERATING INSTRUCTIONS





























Fig. 5. Setting Current Limit.

Setting Current Limit

1. Determine the maximum safe current for the device to be

powered.

2. Temporarily short the (+) and (-) terminals of the power

supply together with a test lead.

3. Rotate the Coarse VOLTAGE control away from zero

sufficiently for the CC indicator to light.

4. Set the meter selection switch to the A position to select the

current metering mode.

5. Adjust the CURRENT control for the desired current limit.

Read the current value on the LED display.

6. The current limit (overload protection) has now been preset.

Do not change the CURRENT control setting after this step.

7. Remove the short between the (+) and (-) terminals and hook

up for constant voltage operation.