SPECIFICATIONS






























“A” AND “B” SUPPLIES
Output Voltage Range:

0V to 30V (model 1760A)
0V to 35V (model 1761)
0V to 60V (model 1762)

Output Current Limit Range:

0.1A to 2A (model 1760A and 1762)
0.1A to 3A (model 1761)

Load Regulation (Constant Voltage):

≤0.01% + 3 mV

Line Regulation 108 - 132 V (Constant Voltage):

≤0.01% + 3 mV

Ripple (Constant Voltage):

≤1 mV RMS

Recovery Time (Constant Voltage):

≤100 uS

Temp. Coefficient (Constant Voltage):

<300 ppm/°C

Load Regulation (Constant Current):

≤0.2% + 3mA

Line Regulation 108 - 132 V (Constant Current):

≤0.2% + 3mA

Ripple Current (at 108 V for Constant Current):

≤3mA RMS

Tracking (Series) Accuracy:

±0.2% + 10mV

Tracking Series, “B” tracks “A”:

5% to 100%

Panel Meter Accuracy (Volts):

±0.5% + 9 digits.*

Panel Meter Accuracy (Current):

±0.5% + 9 digits.*

(* see note 1)

“Third” SUPPLY
Output Voltage Range:

4V to 6.5V (2V to 6.5V model 1761)

Load Regulation (Constant Voltage):

≤10mV (0 to 5A load)

Line Regulation 108 - 132V (Constant Voltage):

≤10mV

Ripple and Noise:

≤2mV RMS

Over Voltage Protection Threshold:

6.8V to 7.3V

Panel Meter Accuracy:

Same as “A” Supply Meter.