MAINTENANCE

WARNING

The following instructions are for use by qualified personnel only. To
avoid electrical shock, do not perform any servicing other than
contained in the operating instructions unless you are qualified to do
so.

FUSE REPLACEMENT

If the fuse blows, the CV or CC indicators will not light and the

power supply will not operate. The fuse should not normally open
unless a problem has developed in the unit. Try to determine and
correct the cause of the blown fuse, then replace only with a fuse of
the correct rating as listed below. The fuse is located on the rear panel
(see Fig. 2).

OPERATION

FUSE VALUE

TYPE

120 V

6 A

SLOW BLOW

220/230/240 V

3 A

SLOW BLOW

Table 1. Fuse Values.

LINE VOLTAGE CONVERSION, INTERNATIONAL
UNITS

The primary winding of the power transformer is tapped to

permit operation from 120/220/230 or 240 VAC, 50/60 Hz
line voltage. Conversion from one line voltage to another is
done by a simple position change of the fuse receptacle
underneath the line cord.

ADJUSTMENTS

This unit was accurately adjusted at the factory before

shipment. Readjustment is recommended only if repairs have
been made in a circuit affecting adjustment accuracy, or if
you have a reason to believe the unit is out of adjustment.
However, adjustments should be attempted only if a
multimeter with an accuracy of ±0.5% DCV or better is
available (B+K Precision Model 2703B or equivalent).