SECTION - 2

SPECIFICATIONS

OUTPUT VOLTAGE

:

0-16V DC continuously variable with coarse
and fine voltage controls.

LOAD CURRENT

:

0-50 Amp max., continuously variable with
coarse and fine controls.

CONSTANT VOLTAGE MODE
REGULATION
LINE

:

Less than ± 0.01% ± 2mV for ±10% change in
line voltage.

LOAD

:

Less than ± 0.01% ± 2mV for load change from
zero to full load.

RIPPLE & NOISE

:

Less than 1mV rms max.(20 Hz - 20 MHz)

CONSTANT CURRENT MODE
REGULATION
LINE

:

Less than ± 0.05% ±10mA for ±10% change in
line voltage.

LOAD

:

Less than ±0.05% ±10mA for change in output
voltage from 0 volts to maximum output voltage.

RIPPLE & NOISE

:

Less than 3mA rms.

OVERLOAD PROTECTION

:

Automatic overload and short circuit protection.

TRANSIENT RESPONSE

:

100µsecs to within 10mV of set output voltage
for load change from 10% to 90%.

STABILITY :
Total drift within 8 hours,after

: ± 0.2% ± 10mV in constant voltage mode.

warm up under constant line,

: ± 0.5% ± 10mA in constant current mode.

load & temp.
PANEL METERS

:

Digital panel meters(marked V for voltmeter and
A for ammeter) are provided with an accuracy of
± 3 counts.

MODE INDICATION

:

Respective LED lights up when the unit is
working in CV or CC mode.

SET LIMIT/ ON-OFF

:

Push Switches for Limit ( V & A ) and output

CONTROLS

ON/OFF setting.

OUTPUT CONTROLS

:

Single turn coarse and fine voltage and current
controls are provided on the front panel

EXTERNAL PROGRAMMING : Output voltage can be programmed by a variable

resistance of 10K

OPERATING TEMPERATURE

:

0-40°C.

INPUT VOLTAGE

:

120/230V AC, ± 10% 47 - 63Hz single phase.

DIMENSIONS

:

19"(W ) x 15.75"(D) x 5.24"(H).

WEIGHT

:

50 lbs. Net.