Specifications – B&K Precision 1655A - Manual User Manual

Page 6

Advertising
background image

4

SPECIFICATIONS

MODEL 1655A

OUTPUT ISOLATION

Leakage less than 0.1mA (25ºC, 50% relative humidity.)

VOLTAGE ADJUSTMENT RANGE

0-150VAC, with input at 120VAC

VOLTAGE/CURRENT SENSING

Sine wave average, calibrated in RMS

MAXIMUM CURRENT (Isolated)

3A continuous, 4A intermittent (0-130V). Intermittent not to

exceed 4 minutes at 4A followed by 5 minutes at 1A max.

METER SCALES

Voltage ....................................................................:0-150V
Current:. .......................................................................0-2A
.........................................................................0-4A
Volt-Amps (Voltage Set to 120)............................ 0-240VA
................................................................. 0-480VA
Leakage ......................0 to 5mA (5,000µA), expanded scale

METER ACCURACY (25ºC)

Volts:.........±5%

(typical) of full scale (calibrated @ 120VAC)

Current:.............................................±5%

(typical) of full scale

Leakage:............................................................±5% @ 500µA

MODEL 1653A

OUTPUT ISOLATION

Leakage less than 0.1mA (25ºC, 50% relative humidity)

VOLTAGE ADJUSTMENT RANGE

0-150VAC, with input at 120VAC

VOLTAGE/CURRENT SENSING

Sine wave average, calibrated in RMS.

MAXIMUM CURRENT (Isolated)

2A continuous (0-130V).

METER SCALES

Voltage:.........................................................................0-150V

Current:.............................................................................0-2A

METER ACCURACY (25ºC)

Volts:........±5%

(typical) of full scale (calibrated @ 120VAC)

Current:............................................±5%

(typical) of full scale

Advertising