4: Color Bars












Color Bars 75%
Same as the top of the SMPTE Bars Pattern

Description:

Seven equal-width vertical bars with 75% (gray) at left, followed by three primary and

three secondary colors. Color bars are at 100% saturation with 75% amplitude.

Pattern Usage:

Use as an overall check of a display device’s capability of producing fully saturated

primary and secondary colors. Especially helpful in detecting full (or partial) loss of colors in older
displays. Also good as a reference input signal when troubleshooting and signal tracing color amplifier or
color demodulator problems within a display device.

Examples of Uncalibrated Displays:

The following images indicate a TV with incorrect hue settings.

Adjust the Hue (or Tint) setting so the first bar appears white (or gray).

Too Red

Too Green

Too Blue



Advertising