Using the GPS

Electrical Connections

The GPS unit sends data to the logging device via an RS232 serial
connection.

The wiring between the GPS connector and the logging device should be as
short as possible, preferably less than 1 m (3 ft)

The following table shows how to wire the GPS unit to a number of MoTeC
logging devices.

GPS
Pin

GPS
Name

Logging
Device
Name

ADL2

SDL

ACL

1

Bat -

Bat -

7

4

Bat- from VIM

2

TX RX 79

34 15

3

RX

Not Used

4

5V 5V 18

etc

14 Requires

5V

from VIM

Note that the ADL2 and SDL logging devices only have one serial connection
therefore if an ECU is to be connected then it must be connected via CAN
(Note that not all ECUs have a CAN connection)

GPS Configuration

The GPS comes preconfigured from MoTeC to suit MoTeC's data loggers.